Descargar Imprimir esta página

Dea NET724 EVO Instrucciones De Uso Y Advertencias página 50

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 107
NET724 EVO
SAFETIES parameters (
SA.01
PHOTO_1
• 000: STOP & CLOSE - The photocell input is active before movement; a trigger will prevent movement. During
closing a trigger will reverse movement.
• 001: ALWAYS - The photocell input is always active. With the gate stationery a trigger will prevent movement.
During opening a trigger will stop the gate until trigger removed. During closing a trigger will reverse the movement
of the gate.
• 002: CLOSE - The photocell input is active only on closing, a trigger will reverse the movement of the gate.
SA.02
PHOTO_2
• 000: STOP & CLOSE - The photocell input is active before movement; a trigger will prevent movement. During
closing a trigger will reverse movement.
• 001: ALWAYS - The photocell input is always active. With the gate stationery a trigger will prevent movement.
During opening a trigger will stop the gate until trigger removed. During closing a trigger will reverse the movement
of the gate.
• 002: CLOSE - The photocell input is active only on closing, a trigger will reverse the movement of the gate.
SA.03
SAFETY_1
• 000: Sensitive edge always enabled
• 001: Sensitive edge enabled only during closing
• 002: Sensitive edge enabled only during closing and before each movement
• 003: Sensitive edge enabled only during opening
• 004: Sensitive edge enabled only during opening and before each movement
SA.04
SAFETY_2
• 000: Sensitive edge always enabled
• 001: Sensitive edge enabled only during closing
• 002: Sensitive edge enabled only during closing and before each movement
• 003: Sensitive edge enabled only during opening
• 004: Sensitive edge enabled only during opening and before each movement
SA.05
"CLOSE IMMEDIATELY" activation
• 000: Disabled
• 001: Active only for PHOTO_1
• 002: Active only for PHOTO_2
• 003: Active for PHOTO_1 and PHOTO_2
SA.06
"CLOSE IMMEDIATELY" behaviour
Allows for defi ning the behaviour when a photocell with "close immediately" mode enabled is crossed during an
opening manoeuvre.
• 000: Completes the full opening manoeuvre fi rst and then closes the gate again with the delay set in tI.20;
• 001: Interrupts the manoeuvre and then closes the gate again with the delay set in tI.20.
SA.07
Reversal due to obstacle during opening
Allows for adjusting the duration of
the reversal of motion if an obstacle
is detected during the opening
manoeuvre.
SA.08
Reversal due to obstacle during closing
Allows for adjusting the duration of
the reversal of motion if an obstacle
is
detected
manoeuvre.
SA.09
Automatic closing time (TCA) with EMERGENCY_IN
Describes the behaviour of the TCA in combination with the EMERGENCY_IN function
• 000: If TCA is active, the gate re-closes after the TCA;
• 001: Even if TCA is active, the gate does not re-close automatically. The fi rst re-closing manoeuvre requires a
command. On the successive manoeuvre, the TCA works normally.
SA.10
Safety device auto-test
The function switches off the 24V_TEST input and verifi es the opening of the
safety device contact before each manoeuvre.
Warning: for operation in the "Safety device auto-test" mode, the following
elements must be connected:
- The transmitters (TX) on the 24V_TEST output;
- The receivers (RX) on the 24V output;
Moreover, the safety devices must be wired and aligned before the path is
learned (SE.03).
48
)
• 000: Complete reversal after an obstacle
• >000: Duration of the reversal after obstacle
(1s..................10s)
• 000: Complete reversal after an obstacle
• >000: Duration of the reversal after obstacle
during
the
closing
(1s..................10s)
Default
Default
TYPE 00
TYPE 04
002
002
000
002
000
001
000
001
000
000
000
000
003
003
003
003
000
000
000
000
• 000: Disabled
• 001: Enabled

Publicidad

loading

Productos relacionados para Dea NET724 EVO