Descargar Imprimir esta página

Easy" Parameters List - Dea NET724 EVO Instrucciones De Uso Y Advertencias

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 107
NET724 EVO
Possible fault on encoder channel 1
Possible fault on encoder channel 2

8 "EASY" PARAMETERS LIST

NOTE When a parameter of the PRO list is changed from its default value, it will appear in the EASY list.
SE.03
Motor stroke learning
SE.04
Motor running direction
RA.02
Learning of remote controls
RA.04
Radio coding
RA.05
Remote control button 1
RA.06
Remote control button 2
IO.03
INPUT 3
IO.04
INPUT 4
TI.01
Automatic closing time
TI.02
Pedestrian automatic closing time
TE.01
Control board input status display
SE.03
Motor stroke learning
RA.02
Learning of remote controls
RA.04
Radio coding
RA.05
Remote control button 1
RA.06
Remote control button 2
TI.01
Automatic closing time
TE.01
Control board input status display
40
Verify that the encoder is properly connected. If the wiring is correct,
perhaps encoder channel 1 is faulty. Set the control unit to function
with only 1 encoder channel (SY.04=001), but it is necessary to invert
the CH1-CH2 wires of the encoder.
If the error persists, replace the electric motor
Verify that the encoder is properly connected. If the wiring is correct,
perhaps encoder channel 2 is faulty. Set the control unit to function
with only 1 encoder channel (SY.04=001).
Warning: The encoder's precision will be reduced
TYPE 00 -
(SLIDING GATES)
TYPE 04 -
(SECTIONAL DOORS)
Default
-
000
-
000
001
000
013
015
000
000
-
Default
-
-
000
001
000
000
-

Publicidad

loading

Productos relacionados para Dea NET724 EVO