Automatic close time (TCA) reload
It allows you to defi ne if, with the gate open and TCA active, the TCA is
reloaded. The function is valid both for the TCA (tI.01) and for the TCA_PED
(tI.02).
If = 1, with the gate completely open, an intervention on PHOTO, OPEN,
OPEN_INT or OPEN_EXT reloads the TCA.
With the gate open in pedestrian mode, an intervention on PHOTO or PED
recharges the TCA_PED, while an OPEN, OPEN_INT or OPEN_EXT command
causes complete opening.
EX.13
Suspend the automatic close time (TCA)
If=0 with the door open and TCA active, the automatic closing always occurs,
even if an impulsive STOP command was given. Only a maintained STOP
command inhibits the automatic closing of the door;
If=1 with the door open and TCA active, an impulse of the STOP command
cancels the automatic closing;
If=2 with the door open and TCA active, an impulse of the STOP or OPEN
command cancels the automatic closing.
Note: If active, the parameter also acts on the TCA_PED function (in this case
the value 002 acts as 001 as an OPEN command with the gate stopped in
pedestrian opening generates a complete opening).
EX.14
Not Used
EX.15
Not Used
EX.16
Not Used
EX.17
Forced hold-to-run
If the function is activated, all inputs confi gured as OPEN and CLOSE
automatically become also OPEN_UP and CLOSE_UP if activated and kept
active for at least 5s, if a safety device (photocell and/or sensitive edge) is
engaged. This function, therefore, can be used to command the automation
even if the safety devices are faulty. If the input is no longer kept activated,
the automation will return to the automatic operating mode.
This function is not available with SAFETY-type safety devices deactivated
with the gate stationary (values 001 and 003 of parameters SA.03 and SA.04).
For safety reasons, we suggest NOT using this function if there are
clocks connected to inputs confi gured as OPEN or CLOSE.
EX.18
Displays the manoeuvres once the board is powered
Allows for integrating the messages on the display during the control unit's
power-on phase, showing the total number of manoeuvres completed.
Warning: The function's activation, and the resulting visualization of new
information on the display, causes the control unit to start more slowly
EX.19
Not Used
EX.20
MANEUVER_INHIBITION function
If an input is set as MANEUVER_INHIBITION it behaves like an NC contact
which, if open, inhibits the maneuver.
NET724 EVO
001
001
• 000: Recharge disabled
• 001: Recharge enabled
000
000
• 000: Disabled
• 001: Active with a STOP impulse
disables TCA.
• 002: Active with a STOP or OPEN
impulse disables TCA.
000
000
• 000: Function disabled.
• 001: Function enabled (automatic
transition to OPEN_UP/CLOSE_UP
with safety devices engaged/faulty
if the OPEN/CLOSE commands are
maintained)
000
000
000:
Visualization
manoeuvres disabled
001:
Visualization
manoeuvres enabled
000
000
• 000: if open, it inhibits opening
commands
but
allows
commands.
• 001: if open, it inhibits opening and
closing commands.
of
total
of
total
closing
51