Descargar Imprimir esta página

Panasonic EYADA Serie Manual De Instrucciones página 19

Ocultar thumbs Ver también para EYADA Serie:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SETTING VIA A WEB BROWSER
Fastening time
[Functional overview]
You can determine the fastening
status by the rotation time of
screw fastening.
Set the lower limit and upper limit
of the fastening time that is judged
as Fastening OK.
For the rotation time, refer to
"Fastening time (s)" in "History
Data" and set an appropriate
value depending on the work.
• The lower limit setting must not be
higher than the upper limit setting.
[Default value]
• Upper limit OFF
• Lower limit OFF
[Setting value]
• Upper limit OFF
Disable
ON
Enable / 0.00* s to 9.99 s
• Lower limit OFF
Disable
ON
Enable / 0.00* s to 9.99 s
Entering the value with (*) will disable the function.
36
EN
(cont.)
When the lower limit and the upper limit
are set to 0.30 and 0.60 respectively
Fastening
Fastening
Fastening
NG (NOK)
OK
NG (NOK)
Snugs in
Snugs in
Snugs in
0.10 s
0.50 s
0.80 s
Fastening OK if the rotation time until snugging
is within 0.30 to 0.60 s.
Soft start
[Functional overview]
You can set the duration of soft start and
the number of rotations during soft start.
• The duration of soft start must not be
shorter than the start time of soft snug.
• Because of the structure of the motor, it
requires some time to increase the speed
of the soft start to the normal speed.
What is soft start?
In order to prevent cross threading and screw galling, initially a screw is rotated
slowly at the beginning of fastening.
[Default value]
• Continue time
0.00 s
• Rotation level
10 Lv
[Setting value]
• Continue time
0.00* s to 9.99 s
• Rotation level
1 Lv to 10 Lv
Soft start speed level (Rotations/minute)
Level
1
EYADA218WA ・ WB
450
EYADA212WA ・ WB
300
EYADA407WA ・ WB
160
* Relative to the maximum
About 25%
number of rotations
Level
6
EYADA218WA ・ WB
1200
EYADA212WA ・ WB
800
EYADA407WA ・ WB
430
* Relative to the maximum
number of rotations
• The values (numbers of rotations) are only guidelines.
Entering the value with (*) will disable the function.
Soft snug
Soft start
time
time
Working
Work start
Fastening OK
(Rotating)
2
3
4
600
750
900
400
500
600
220
270
330
About 50%
7
8
9
1350
1500
1650
900
1000
1100
490
540
600
About 75%
About 100%
5
1050
700
380
10
1800
1200
650
37
EN

Publicidad

loading

Este manual también es adecuado para:

Eyada212waEyada218waEyada407waEyada212wbEyada218wbEyada407wb