SETTING VIA A WEB BROWSER
Ignore count time
[Functional overview]
You can set screws not to be
counted even if they are fastened
again after being determined as OK.
Set the duration of fastening to
exclude from counting after
fastening is determined as OK.
• Counting is still enabled when you
reverse rotations to redo or loosen
screws.
• When both the "Ignore count time"
and the "Disable fastening time"
are enabled, the "Disable fastening
time" takes precedence.
[Default value]
0.00 s
[Setting value]
0.00* s to 9.99 s
Count return
[Functional overview]
You can set how fastened screws
determined as OK are counted
when reversing rotations to redo
or loosen them.
[Default value]
Return 1 count
[Setting value]
Don't change
Reverse rotations are not counted.
Return 1 count
The count is put back by reverse rotations.
Return to start
The count is reset by reverse rotations.
Entering the value with (*) will disable the function.
42
EN
(cont.)
Fastening OK
Count
ignored
Fastening is
executed during
the set time.
After being determined as OK, screws will
not be counted during the time to ignore
counting even if they are fastened again.
When it is set to "Return 1 count"
1
The count
goes back
by one.
The 2nd screw is
redone.
(Reverse rotations)
Batch complete judgement waiting time
[Functional overview]
You can set the waiting time from
when the last screw fastening is
determined as OK to when it is
determined as count-up (count
complete).
During the set waiting time, you
can reverse rotations after
finishing the last screw set in the
count quantity.
• Forward rotations are not allowed
during the waiting time.
[Default value]
0.00 s
[Setting value]
0.00* s to 9.99 s
Count method
[Functional overview]
You can switch count methods for
2
screw fastening.
[Default value]
Count down
[Setting value]
Count down
The number of fastened screws is counted from the set value
down to 0.
Count up
The number of fastened screws is counted from 0 up to the set
value.
Entering the value with (*) will disable the function.
When it is set to "3.00"
Reverse rotations are
allowed for 3.00 s.
After the last screw fastening is determined
as OK, no count-up will occur for 3.00 s,
allowing you to reverse rotations to redo or
loosen screws.
Count-down mode
Count-up mode