Safety Shutoff; Open The Axon-Bus Gripping Component In An Emergency; Bluetooth Function; Beep Function - Ottobock Axon Arm Hybrid 12K500 Serie Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 75
Handling
1. With the Axon-Bus prosthetic system switched on, press the charging receptacle button (Fig. 2, arrow) and
hold for less than one second.
2. The LED is illuminated. The colour of the LED indicates the current battery charge level.
Battery empty
Battery 50% charged
Battery fully charged

7.5 Safety Shutoff

The purpose of the safety shutoff is to protect the battery; it is triggered in case of:
Excessively high or low temperature
Overvoltage or undervoltage
Short circuit.
After a short circuit the battery charger must be connected and then disconnected in order for the electronics to be
activated.

7.6 Open the Axon-Bus Gripping Component in an Emergency

7.7 Bluetooth Function

Pressing the button in the charging receptacle and holding for more than four seconds with the Axon-Bus prosthet­
ic system turned off activates the Bluetooth function of the connected AxonMaster 13E500. The blue LED lights up.
Once a connection to the PC has been successfully established, the LED flashes blue.

7.8 Beep Function

Action
Switch on the Axon-Bus pros­
thetic system
Press and hold the button for one
to four seconds.
Switch off the Axon-Bus pros­
thetic system
Press the button and hold for
more than one second.
Charge the Axon-Bus prosthet­
ic system
Connect charging plug, charging
process starts.
Stop charging
Disconnect charging plug. Char­
ging ends and the Axon-Bus
prosthetic system is switched off.
Empty battery indicator
Switch on the Bluetooth func­
tion (if the Axon-Bus prosthetic
system was previously switched
34 | Ottobock
Orange LED is illuminated
Yellow LED is illuminated
Green LED is illuminated
This safety function allows the Axon-Bus gripping component to be opened regard­
less of the control signals present.
1) With the Axon-Bus prosthetic system switched on, press the charging receptacle
button and hold for approximately three seconds until the Axon-Bus gripping
component begins to open. A pulsating beep sounds as it opens.
2) Releasing the button immediately stops the process of opening the Axon-Bus
gripping component and turns the entire Axon-Bus prosthetic system off.
Beep
Beep
1x long
2x short
Beep
Beep
Beep
3x short
1x
pulsating
short,
1x long
AxonArm Hybrid 12K500=*, AxonArm Ergo 12K501=*