Operation of the Unit

2.1.1 Keyboard

GB
GB
GB- 10
When switching on KEB COMBIVERT F5 the value of parameter CP.1
appears. (see Drive mode to switch the keyboard function)
The function key (FUNC)
changes between the
parameter value and
parameter number.
With UP and DOWN the
value of the parameter
number is increased/
decreased
with
changeable parameters.
Principally during a change, parameter values are immediately accepted
and stored non-volatile. However, with some parameters it is not useful
that the adjusted value is accepted immediately . In these cases (CP.17,
CP.18, CP.22, CP.26, CP.29, CP.31, CP.32, CP.34, CP.35) the adjusted
value is accepted an stored non-volatile by pressing ENTER.
If a malfunction occurs during operation, then the actual display is
overwritten by the alarm message. The alarm message in the display is
reset by ENTER.
error
With ENTER only the error message in the display is reset.In
the inverter status display (CP.3) the error is still displayed. In
order to reset the error itself, the cause must be removed or a
power-on reset must be made.