Drive Mode
2.7 The Drive Mode
GB
2.7.1
Start / Stop Drive
GB
2.7.2 Changing the
Direction of
Rotation
2.7.3 Preseting the
Set Value
2.7.4 Leaving the
Drive Mode
GB- 28
The Drive Mode is a operating mode of KEB COMBIVERT that permits
the manual starting of the drive by the operator. After switching the control
release the set value and rotation setting are effected exclusively over the
keyboard. In order to activate the Drive Mode the corresponding password
(see last but one page) must be entered in CP.0. The display switches
over as follows.
Direction of rotation
F=forward / r=reverse
Modulation blocked
Drive not controlled
Drive accelerates onto
the adjusted set value
To exit the drive mode the inverter must be in status "stop" (Display noP
or LS). Press the FUNC and ENTER keys simultaneously for about 3
seconds to leave the drive mode. The CP-parameters appear in the
display.
+
Status
noP = no control release /
LS = neutral position
Drive decreases to 0 Hz and
switches the modulation off
Drive operates with
adjusted set value
Drive changes direction
of rotation
Display changes when key is
pressed to set value display/
presetting
Set value can be changed
with UP/DOWN at pressed
FUNC/SPEED key
for 3 seconds