Basic Adjustment Of The Drive - KEB COMBIVERT F5 Serie Manual De Instrucciones

Ocultar thumbs Ver también para COMBIVERT F5 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 143
Operation of the Unit
Intermediate circuit
voltage/Peak value
Output voltage
GB
2.5 Basic Adjustment
of the Drive
GB
Minimum frequency
Maximum frequency
GB- 14
CP.8 makes it possible to recognize short-time voltage rises within an
operating cycle. For that the highest value of CP.7 is stored in CP.8. The
peak value memory can be cleared by pressing the UP, DOWN or ENTER
key or over bus by writing any value you like to the address of CP.8. The
switch off of the inverter also clears the memory.
Display of the actual output voltage in volt.
The following parameters determine the fundamental operating data of
the drive. They should be checked and/or adapted to the application.
With this frequency the inverter operates without presetting an analog set
value. Internal limiting of the fixed frequencies CP.19...CP.21.
Adjustment range:
Resolution:
Factory setting:
With this frequency the inverter operates with maximum analog set value.
Internal limiting of the fixed frequencies CP.19...CP.21.
Adjustment range:
Resolution:
Factory setting:
f
0...400 Hz
CP.11
0,0125 Hz
0,0 Hz
CP.10
0V
0...400 Hz
0,0125 Hz
70 Hz
U
REF
10V

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Combivert f5 compactCombivert f5 generalCombivert f5 basic

Tabla de contenido