Machine
Measured sound
power level
2000/14/EC
(ISO 3744)
Uncertainty for
en
measured sound
power level
Guaranteed sound
power level LwA
2000/14/EC (ISO
3744)
Vibration value*
ahv,eq front/rear
grip ISO 19432 (EN
12096)
Uncertainty for vi-
bration value
Comment
5 Safety instructions
In addition to the information relevant to safety given
in each of the sections of these operating instructions,
the following points must be strictly observed at all
times.
5.1 General safety rules
a) Use the right tool or machine for the job. Do not
use the tool or machine for purposes for which
it was not intended. Use it only as directed and
when in faultless condition.
b) Avoid touching rotating parts. Switch the power
tool on only after bringing it into position at the
workpiece. Touching rotating parts, especially ro-
tating drill bits, discs or blades, etc. may lead to
injury.
c) Use only the genuine Hilti accessories or ancillary
equipment listed in the operating instructions. Use
of accessories or ancillary equipment not listed in the
operating instructions may present a risk of personal
injury.
d) Always hold the saw and the saw carriage se-
curely with both hands on the grips provided.
Keep the grips dry, clean and free from oil and
grease.
e) Cuts made in loadbearing walls of buildings or other
structures may influence the statics of the structure,
especially when steel reinforcing bars or load-bearing
components are cut through. Consult the structural
26
DSH 700 30 cm
DSH 700 35 cm
/ 12"
/ 14"
108 dB (A)
108 dB (A)
2.5 dB (A)
2.5 dB (A)
111 dB (A)
111 dB (A)
4.5 / 3.2 m/s²
4.7 / 5.0 m/s²
2.4 / 2.1 m/s²
2.2 / 2.1 m/s²
* The sound pres-
* The sound pres-
sure level and the
sure level and the
vibration values
vibration values
were determined
were determined
allowing for 1/7 no-
allowing for 1/7 no-
load operation and
load operation and
6/7 full-load opera-
6/7 full-load opera-
tion.
tion.
DSH 900 35 cm
/ 14"
112 dB (A)
2.5 dB (A)
115 dB (A)
6.3 / 6.2 m/s²
1.9 / 2.7 m/s²
* The sound pres-
sure level and the
vibration values
were determined
allowing for 1/7 no-
load operation and
6/7 full-load opera-
tion.
engineer, architect, or person in charge of the
building project before beginning the work.
f)
Do not overload the machine. It will work more
efficiently and more safely within its intended per-
formance range.
g) Never use the power tool without the guard
(hood).
h) Take steps to ensure that flying sparks from the
power tool do not present a hazard, i.e. by striking
yourself or other persons. Adjust the position of
the disc guard accordingly.
i)
Adjust the position of the disc guard on the ma-
chine correctly. The guard must be securely at-
tached to the machine and positioned for max-
imum safety, so the least amount of cutting disc
is exposed towards the operator. The guard helps
to protect the operator from broken disc fragments
and accidental contact with the disc.
j)
Store machines in a secure place when not in use.
When not in use, machines must be stored in a
dry, high place or locked away out of reach of
children.
k) Switch the machine off before transporting it.
l)
When laying the machine down, make sure that it
stands securely.
m) Switch the machine off after use.
n) Have your power tool serviced by a qualified repair
person using only identical replacement parts.
DSH 900 40 cm
/ 16"
112 dB (A)
2.5 dB (A)
115 dB (A)
5.2 / 4.5 m/s²
2.3 / 2.1 m/s²
* The sound pres-
sure level and the
vibration values
were determined
allowing for 1/7 no-
load operation and
6/7 full-load opera-
tion.