9: Terminal encoder provision (X1,X2 terminal connect to the encoder
orthogonal input)
10~14: Reserved
Assist frequency provision:
0: keypad analog potentiometer provision;
1: AI1 analog setting;
2: AI2 analog setting;
3: Terminal UP/DOWN adjustment provision;
4: Communication provision (Modbus and external bus share a main frequency
memory);
5: EAI1 analog setting (extend effective);
6: EAI2 analog setting (extend effective);
7: High speed pulse provision (X8 terminal need select the corresponding
function);
8: Terminal pulse width provision (X8 terminal need select the corresponding
function);
9: Terminal encoder provision (X1,X2 terminal connect to the encoder
orthogonal input)
10~20: Reserved
5.1.3. Work state
Work state of TDS600 includes of Waiting state, Running state and Parameter
setting state.
Waiting state:
If there is no running command after the inverter electrified or after stop
command during running state, the inverter enters into waiting state.
Running state:
The inverter enters into running state after receiving run command.
Parameter setting state:
After receiving the parameter identification command, enter the parameter
setting state, after turning into the shutdown state.
154