7.3. Failure reset
01.
Before reset you must fi nd out reason of failure downright and
eliminate it, otherwise may cause permanent damage to the inverter.
02.
If can't reset or failure takes place again after resetting, should
look for reason and continuous resetting will damage the inverter.
03.
Reset should take place 5 minutes later after overload, overheat
protection action.
04.
For the fault of E-14, the reset is invalid, the motor wiring should
be checked after power off, and restart the inverter.
05.
When there is a fault of E-16 after power on, do not directly run the
inverter after reset, and need to check whether the input, out wiring
To resume normal running when failure takes place in the inverter, you can
choose following any kind of operation:
01. After you set any terminal of X1~X8 to be inputted by external RESET, it
will be reset after connected to COM.
02. When failure code is displayed, press
be restoration.
03. Communication reset. Please refer to annex description.
04. Cut off power supply.
7.4. Alarm reset
When an alarm occurs, must eliminate alarm source which cause alarm,
otherwise the alarm cannot be eliminated, also cannot be reset by reset button.
218