F00.20
Analog input
terminal
configuration
F00.21
Analog output
terminal
configuration
F00.22
Y output
terminal
configuration
F00.23
G/P type setup
F00.24
Motor control mode
F00.25
Monitoring
parameter 2
selection
F00.26
Busbar voltage
adjustment
coefficient
. units digit:AI1 configuration
0:0~10V input
1:4~20mA input
. tens digit: AI2 configuration
0:-10~10V input
1: 4~20mA input
. hundreds digit: EAI1 configuration
0:0~10V input
1:-10~10V input
2:4~20mA input
. thousands digit: EAI2 configuration
0:0~10V input
1:-10~10V input
2:4~20mA input
. units digit: AO1 configuration
0: 0~10V output
1: 4~20mA output
. tens digit: AO2 configuration
0: 0~10V output
1: 4~20mA output
. hundreds digit: EAO1 configuration
0: 0~10V output
1: 4~20mA output
. thousands digit: EAO2 configuration
0: 0~10V output
1: 4~20mA output
. units digit~ . hundreds
digit: reserved
. thousands digit: Y4 output configuration
0: Open collector output
1: DO output
0: G type.
1: P type.
Note: P type is only for V/F control
0: V/F control (object to torque control)
1: speed less sensor vector control 1
(compare to speed less sensor vector
control 2, this control mode is more suitable
for asynchronous motor≤160KW, support
speed and vector control)
2: speed sensor vector control (support
asynchronous motor speed and torque
control)
3: speed less sensor vector control 2 (only
support asynchronous motor speed control,
this control mode is more suitable for motor
≥185KW)
The same as parameter F00.01
0.900~1.100
6. Function parameter schedule graph
1
0000
1
0000
1
0000
1
0
1
0
1
2
1
1.000
×
×
×
×
×
o
o
171