F19.10
Motor underload
alarm detection action
F19.11
Input& output phase
loss, short circuit
detection action
F19.12
Over voltage stall
selection
F19.13
Over voltage stall
protection voltage
F19.14
Automatic current limit
level
F19.15
Frequency decline rate
of automatic current
limit
F19.16
Automatic current limit
action selection
F19.17
Rapid current-limiting
coefficient
F19.18
Motor run section
selection when instant
power off
F19.19
Frequency droop rate
when instant power off
F19.20
Voltage rebound
estimate time when
instant power off
F19.21
Action estimate voltage
when instant power off
F19.22
Allowed the longest
off time when instant
power off
F19.23
Terminal external device
fault action selection
F19.24
Power on terminal
protection selection
F19.25
Provide lost detection
value
F19.26
Provide lost detection
time
. units digit: detection selection
0:no detection
1:detection all the time when run
2:detection only when constant velocity
. tens digit: action selection
0:alarm, continuous run
1:alarm, stop run as halt mode
2:fault, free halt
. units digit: input phase loss
0:no detection
1:fault, free halt
. tens digit: output phase loss
0:no detection
1:fault, free halt
. hundreds digit: power-on on earth short
circuit protect detection enable
0:no detection
1:fault, free halt
. thousands digit: operation on earth short
circuit protect detection enable
0:no detection
1:fault, free halt
0:forbid
1:allowed
120~150% (rated busbar voltage)
110~230% (G type rated current)
0.00~99.99Hz/s
0:constant velocity invalid
1:constant velocity valid
150%~250% (G type rated current)
0:forbid
1:allowed
0.00~99.99Hz/s
0.00~10.00s
60~100%(rated busbar voltage)
0.30~5.00s
0:alarm, continuous run
1:alarm, stop run as halt mode
2:fault, free halt
0:invalid
1:valid
0~100%
0.0~6000.0s
6. Function parameter schedule graph
1
1
1111
1
1%
125%
1%
150%
0.01Hz/s
10.00Hz/s
1
1%
210%
1
0.01Hz/s
10.00Hz/s
0.01s
0.10s
1%
80%
0.01s
2.00s
1
1
1%
0.1s
0.5s
00
o
o
1
×
×
×
×
0
×
×
0
×
×
×
×
×
2
×
1
×
0%
o
o
201