Alarms Description - Angelo Po COMBIFIT CF623E Manual De Instalación, De Uso Y De Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 192
10. Alarms description
If an alarm is triggered, on temperature and time display is shown the
name of the alarm triggered.
The alarms managed are the following
Name
Description
Chamber
Chamber probe
probe
failure
Pin
Pin probe failure
probe
Safety
Motor Alarm
motor
Peripheral
Motor Inverter
Alarm
Chamber
Chamber thermal
safety switch
breaker
Hi temp
Temperature inside
the technical
compartment is too
high
No
There is no water to
water
generate steam
Communica-
Main board
tion
communication
failure
Power fail
Electric power
supply is
interrupted
Probe 4
Moisture control
probe 4 alarm
Probe 5
Moisture control
probe 5 alarm
38
Actions
SOLUTION
Cooking
Replace the chamber probe.
cycle block;
automatic
reset.
Manual reset.
Replace the pin probe.
Cooking
If the problem persists, contact
cycle block;
the support center.
automatic
reset.
Cooking
Cut off the power and power
cycle block;
again.
automatic
If the problem persists, contact
reset.
the support center.
Cooking
If the problem persists, contact
cycle block;
the support center.
automatic
reset.
Cooking
Check the perimeter of the oven
cycle block;
(slits) and the correct operation
automatic
of parts cooling fans.
reset.
Clean the ventilation filter
(see section 6.2 page 32).
Cooking
Check the connection to water
cycle block;
pipeline and make sure the shut-
automatic
off valve is open.
reset.
Cooking cycle
Cut off the power and power
block.
again. If the problem persists,
contact the support center.
Cooking cycle
Press M for 1 second.
block.
Cooking cycle
Replace the moisture control probe
block.
4
Cooking cycle
Replace the moisture control probe
block.
5
COMBIFIT
installation, use and maintenance manual

Publicidad

Tabla de contenido
loading

Tabla de contenido