Model EQPLBS
Nominal cooling capacity (*)
EER
ESEER +
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*) kPa
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal flow rate/pressure drop RC100 (±)
Nominal heating capacity DS (±)
Nominal flow rate/pressure drop DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power (*) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical/control power supply
Nominal current (■)
Maximum current (■)
Starting current (■)
Starting current with SFS (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet air temperature 35°C;
chilled water temperature 7°C; temperature differential at evaporator 5 K;
fouling factor equal to 0.35x10
(***) Sound pressure level in dB(A) referring to a 10 m distance from the
unit, in free field and directionality factor equal to Q=2. The noise data
refers to the units without the electric pump
(****) Sound power level in dB(A) on the basis of measurements taken in
accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards
The noise data refers to the units without the electric pump
kW
kW
dB(A)
dB(A)
n° x kW
m³/h
Type
m³/h
kPa
kPa
kPa
kPa
l
kW
m³/h / kPa 80,8/65 88/74 98,7/70 110,9/74 121,4/86 134,1/81 142,9/82 149,9/60 164,1/74 177,3/84 186,7/78 196/86
kW
m³/h / kPa 7,7/5
Kg
Kg
kW
kW
V-ph-Hz
V-ph-Hz
A
A
A
A
A
mm
mm
mm
Ø
Ø
Kg
-4
m
2
K/W.
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
4360 4390 4435 5500 6540 6590 6635 6670 7730 8790 8830 8860
352
376
418
480
519
2,79
2,65
2,63
2,81
2,72
4,75
4,65
4,62
4,84
4,74
350,9 374,7 416,7 478,4 517,1 560,1 611,9 637,8 705,6 752,3 790,4 825,1
2,76
2,62
2,6
2,77
2,68
4,11
4,02
4
4,17
4,1
57
58
59
59
59
89
90
91
91
91
4/4
4/4
4/4
5/5
6/6
2
2
2
2
6x1.2 6x1.2
6x1.2
8x1.2 8x1.2 8x1.2 10x1.2 10x1,2 12x1,2 12x1,2 12x1,2 12x1,2
92000 92000 92000
122500 122500 122500 153000 153000 183000 183000 183000 183000
Plates/Shell and tube (STE accessory)
60,5
64,6
71,9
82,5
89,2
36
40
36
41
46
104
94
124
107
89
143
133
183
168
151
95
84
111
99
79
134
122
170
160
141
700
700
700
1000 1000 1000 1000 1000 1000 1000 1000 1000
470
512
574
645
706
90
98
109
124
134
8,4/6
9,4/7 10,7/8 11,5/8 12,9/9 13,6/8 14,7/14 17,2/27 17,5/30 18,4/34 18,7/39
35
35
38
47
47
20,8
20,8
20,8
26
31,2
4360 4390 4435 5500 6540 6590 6635 6670 7730 8790 8830 8860
126,0 142,0 159,0 171,0 191,0 220,0 221,0 232,0 253,0 283,0 300,0 314,0
4,0/5,5 4,0/5,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 7,5/11 7,5/11 7,5/11 7,5/11
230 – 1 – 50 / 24 – 1 – 50
207
233
261
281
314
268
308
326
366
398
494
504
549
588
624
379
397
430
469
509
7,6/10,5 7,6/10,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 14,5/21 14,5/21 14,5/21 14,5/21
4360 4390 4435 5500 6540 6590 6635 6670 7730 8790 8830 8860
2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450
2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260
3740 3740 3740 4840 4840
DN80
DN80
DN80
DN100
DN100
VIC
VIC
VIC
VIC
VIC
2" VIC 2" VIC 2" VIC 2" VIC 2" VIC
2360 2370 2430 2940 3165 3195 3510 3535 4210 4410 4490 4510
(±) Recovery unit heating capacity Conditions referring to the unit
operating with chilled water temperature 7°C, differential
temperature due to evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100) 50/60°C (DS).(
(■) Absorbed power/absorbed current without electric pump.
The peak current refers to the unit's most heavy duty operating
conditions.
(°) Data calculated in accordance with EN 14511:2011 under nominal
conditions.
The refrigerant charge values are indicative. Refer to the serial number
plate.
231
562
614
640
708
2,55
2,78
2,76
2,80
4,66
4,77
4,69
4,71
2,52
2,74
2,72
2,76
4,03
4,13
3,99
4,07
59
59,5
60
60
91
92
92,5
92,5
6/6
6/6
6/6
7/6
2
2
2
2
2
96,6
105,6 110,0 121,7 129,8 136,3
42
44
46
45
95
82
69
98
123
111
94
140
83
68
53
92
111
97
78
134
780
831
872
954
150
158
171
200
86
51
61
61
31,2
31,2
31,2
36,4
400 – 3 – 50
361
363
381
415
458
480
494
556
684
702
717
780
549
582
598
661
480
5940 5940 7150 7150 7150 7150
DN100
DN100
DN100
DN125
VIC
VIC
VIC
VIC
2"1/2
2"1/2
2"1/2
3" VIC 3" VIC 3" VIC 3" VIC
VIC
VIC
VIC
755
793
828
2,67
2,64
2,64
4,63
4,61
4,60
2,63
2,61
2,60
4,01
3,99
3,98
60
60,5
61,5
92,5
93
94
8/6
8/6
8/6
2
2
2
142,4
49
44
48
88
88
79
131
131
122
81
80
70
124
123
114
1031 1091 1140
203
214
218
96
92
92
41,6
41,6
41,6
465
493
516
610
631
653
808
856
877
702
736
758
DN125
DN150
DN150
VIC
VIC
VIC