Model EQPL
Nominal cooling capacity (*)
EER
ESEER +
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*) kPa
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal flow rate/pressure drop RC100 (±)
Nominal heating capacity DS (±)
Nominal flow rate/pressure drop DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power (*) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical/control power supply
Nominal current (■)
Maximum current (■)
Starting current (■)
Starting current with SFS (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser inlet air temperature 35°C;
chilled water temperature 7°C; temperature differential at evaporator 5 K;
fouling factor equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to a 10 m distance from the
unit, in free field and directionality factor equal to Q=2. The noise data
refers to the units without the electric pump
(****) Sound power level in dB(A) on the basis of measurements taken in
accordance with UNI EN-ISO 9614 and Eurovent 8/1 Standards
The noise data refers to the units without the electric pump
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
kW
386
415
462
3,27
3,19
3,16
5
4,97
4,96
kW
385
414 460,8 524,5 569,5 623,1 665,3 695,2 758,3 819,9 870,0 916,8
3,24
3,16
3,13
4,33
4,31
4,3
dB(A)
62,5
63,5
64,5
dB(A)
95
96
97
dB(A)
86
86
87
4/4
4/4
4/4
2
2
2
n° x kW
8x1.8 8x1.8 8x1.8 10x1.8 10x1.8 10x1.8 12x1.8 12x1,8 14x1,8 16x1,8 16x1,8 16x1,8
m³/h
159000 159000 159000 198500 198500 198500 238000 238000 278000 318000 318000 318000
Type
m³/h
66,4
71,4
79,4
27
28
30
kPa
111
103
124
kPa
149
140
185
kPa
105
96
116
kPa
144
134
176
l
700
700
700
kW
487
527
590
m³/h / kPa 83,7/43 90,6/46 101,5/49 114,7/55 124,8/54 137,7/63 146/52 152,9/54 166,5/42 179,5/50 191,0/45 201,7/49
kW
94
102
117
8,1/5 8,8/6 10,1/8 11,2/8 12,2/9 13,7/10 14,2/9
m³/h / kPa
Kg
47
49
51
Kg
20,8
20,8
20,8
4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
kW
118,0 130,0 146,0 163,0 178,0 199,0 209,0 220,0 240,0 258,0 275,0 291,0
kW
4,0/5,5 4,0/5,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 5,5/7,5 7,5/11 7,5/11 7,5/11 7,5/11
V-ph-Hz
V-ph-Hz
A
194
213
240
A
276
316
334
A
502
512
557
A
387
405
438
A
7,6/10,5 7,6/10,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 14,5/21 14,5/21 14,5/21 14,5/21
4385 4415 4460 5525 6570 6625 6665 6700 7760 8820 8870 8920
mm
2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450
mm
2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260
mm
4840 4840 4840 5940 5940 5940 7100 7100 8250 9350 9350 9350
DN80
DN80
DN80
Ø
VIC
VIC
VIC
2" VIC 2" VIC 2" VIC 2" VIC 2" VIC
Ø
Kg
2440 2460 2510 2980 3200 3210 3715 3740 4250 4650 4750 4770
(±) Recovery unit heating capacity Conditions referring to the unit
operating with chilled water temperature 7°C, differential temperature due
to evaporation of 5 K, hot water temperature produced equivalent to
40/45°C (RC100) 50/60°C (DS).
(■) Absorbed current/absorbed power value without electric pump.
The peak current refers to the unit's most heavy duty operating
conditions.
(°) Data calculated in accordance with EN 14511:2011 under nominal
conditions.
The refrigerant charge values are indicative. Refer to the serial number
plate.
232
526
571
625
667
697
3,23
3,21
3,14
3,19
3,17
5,04
5,01
4,99
5,04
4,99
3,19
3,17
3,1
3,16
3,13
4,36
4,34
4,32
4,37
4,29
64,5
64,5
64,5
65,5
65,5
97
97
97
98
87
87
87
88
5/5
6/6
6/6
6/6
6/6
2
2
2
2
Plates/Shell and tube (STE accessory)
90,4
98,2
107,5
114,7
119,8 130,7
34
33
38
32
98
82
86
83
161
147
115
112
88
69
71
66
151
134
100
95
1000 1000 1000 1000 1000 1000 1000 1000 1000
667
726
801
849
889
130
142
159
165
179
15,4/16 17,7/29 18,0/33 19,1/37 19,7/42
61
65
65
83
26
31,2
31,2
31,2
31,2
400 – 3 – 50
230 – 1 – 50 / 24 – 1 – 50
268
292
327
343
361
374
406
466
488
502
596
632
692
710
724
477
517
557
590
604
DN100
DN100
DN100
DN100
DN100
VIC
VIC
VIC
VIC
VIC
2"1/2
2"1/2
2"1/2
VIC
VIC
VIC
760
822
872
919
3,17
3,19
3,17
3,16
5,09
5,09
5,05
5,00
3,14
3,15
3,14
3,13
4,40
4,40
4,37
4,32
65,5
65,5
66,0
67,0
98
98
98
99
100
89
90
90
91
92
7/6
8/6
8/6
8/6
2
2
2
2
2
141,3
149,9
158,0
33
27
33
29
32
74
109
95
91
80
99
152
138
134
124
56
102
86
82
70
80
145
129
125
114
968
1044 1111 1173
206
209
222
229
83
109
115
126
126
36,4
41,6
41,6
41,6
394
424
452
478
564
626
647
669
786
823
870
892
776
716
750
772
DN125
DN125
DN150
DN150
VIC
VIC
VIC
VIC
3" VIC 3" VIC 3" VIC 3" VIC