Model EQPHB
Nominal cooling capacity (*)
EER
ESEER +
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
COP
Nominal heating capacity (**) (°) EN 14511:2013
COP (*) (°) EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*) kPa
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal flow rate/pressure drop RC100 (±)
Nominal heating capacity DS (±)
Nominal flow rate/pressure drop DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power in summer mode (*) (■)
Absorbed power in winter mode (**) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical/control power supply
Summer operation nominal current (*) (■)
Maximum current (■)
Starting current (■)
Starting current with SFS (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5 K; evaporator scaling factor equal
to 0.35x10-4 m2 K/W.
(**) In the following conditions: Evaporator inlet
water temperature 7°C B.S., 6°C B.U.; hot
water temperature 45°C; temperature
differential at condenser 5 K; fouling factor
equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to
a 10 m distance from the unit, in free field and
directionality factor equal to Q=2. The noise
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
4360
4390
kW
348
370
2,83
2,7
4,62
4,51
kW
346,9
368,7
2,8
2,67
4
3,9
kW
373
397
3,03
2,96
kW
374,2
398,4
3,01
2,94
dB(A)
62
dB(A)
94
dB(A)
89
n°
4/4
4/4
n°
2
n° x kW
6x1.8
6x1.8
m³/h
115000
115000
Type
m³/h
59,8
63,6
36
kPa
105
kPa
144
134
kPa
92
kPa
131
119
l
700
700
kW
457
492
78,6/63
84,6/71
m³/h / kPa
kW
90
7,7/5
8,3/6
m³/h / kPa
Kg
68
Kg
20,8
20,8
4360
4390
kW
123
137
kW
123
134
kW
4,0/5,5
4,0/5,5
V-ph-Hz
V-ph-Hz
A
202
225
A
268
308
A
494
504
A
379
397
A
7,6/10,5 7,6/10,5
4360
4390
mm
2450
2450
mm
2260
2260
mm
3740
3740
Ø
DN80 VIC DN80 VIC DN80 VIC DN100 VIC DN100 VIC DN100 VIC DN100 VIC DN100 VIC
2" VIC
2" VIC
Ø
Kg
2700
2710
data refers to the units without the electric
pump
(****) Sound power level in dB(A) on the basis
of measurements taken in accordance with UNI
EN- ISO 9614 and Eurovent 8/1 Standards The
noise data refers to the units without the electric
pump
(±) Recovery unit heating capacity Conditions
referring to the unit operating with chilled water
temperature 7°C, differential temperature due to
evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100)
50/60°C (DS). NB. With heat pumps operating
in winter mode with DC active, the heating
234
4435
5500
412
467
2,68
2,81
4,49
4,57
410,7
465,4
509,1
2,64
2,78
3,89
3,94
436
486
3,05
3
437,4
487,7
3,03
2,98
63
64
64
95
96
96
90
91
91
4/4
5/5
2
2
2
6x1.8
8x1.8
8x1.8
115000
153000
153000
Plates/Shell and tube (STE accessory)
70,8
80,3
40
37
41
96
125
113
183
174
81
106
107
165
167
700
700
551
614
94,8/67 105,6/71 116,4/81 128,3/76 136,7/77 143,9/84
96
108
121
9,3/7
10,4/8
11,4/9
68
91
91
20,8
33
4435
5500
154
166
143
162
5,5/7,5
5,5/7,5
5,5/7,5
400 – 3 – 50
230 – 1 – 50 / 24 – 1 – 50
253
273
326
366
549
588
430
469
10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5
4435
5500
2450
2450
2260
2260
3740
4840
2" VIC
2" VIC
2" VIC 2"1/2 VIC 2"1/2 VIC 2"1/2 VIC
2780
3400
capacity available is decreased from the portion
supplied to the desuper- heater.
(■) Absorbed current/absorbed power value
without electric pump.
The peak current refers to the unit's most heavy
duty operating conditions.
(°) Data calculated in accordance with EN
14511:2011 under nominal conditions.
The refrigerant charge values are indicative.
Refer to the serial number plate
6540
6590
6635
511
555
603
2,75
2,63
2,79
4,54
4,48
4,57
553,2
600,9
2,71
2,6
2,76
3,93
3,88
3,96
528
590
636
2,95
2,99
3,06
530
592,1
638,3
2,93
2,97
3,04
64
64
64,5
96
96
97
91
91
92
6/6
6/6
6/6
2
2
2
8x1.8
10x1.8
153000
191000
191000
87,9
95,4
103,7
46
42
44
94
99
88
156
126
116
86
90
77
148
117
105
700
700
1000
677
746
795
133
145
157
12,5/9
13,5/9
14,2/10
91
94
112
46
46
46
6540
6590
6635
186
211
216
179
197
208
5,5/7,5
5,5/7,5
305
346
355
398
458
480
624
684
702
509
549
582
6540
6590
6635
2450
2450
2450
2260
2260
2260
4840
4840
5940
3580
3640
4080
6670
634
2,79
4,55
631,7
2,75
3,95
669
3,03
671,5
3
64,5
97
92,5
6/6
2
10x1.8
109
48
71
96
59
84
1000
837
165
112
46
6670
227
221
5,5/7,5
373
494
717
597
6670
2450
2260
5940
4120