Model EQPHBS
Nominal cooling capacity (*)
EER
ESEER +
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
COP
Nominal heating capacity (**) (°) EN 14511:2013
COP (*) (°) EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*) kPa
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal flow rate/pressure drop RC100 (±)
Nominal heating capacity DS (±)
Nominal flow rate/pressure drop DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power in summer mode (*) (■)
Absorbed power in winter mode (**) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical/control power supply
Summer operation nominal current (*) (■)
Maximum current (■)
Starting current (■)
Starting current with SFS (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5 K; evaporator scaling factor equal
to 0.35x10-4 m2 K/W.
(**) In the following conditions: Evaporator inlet
water temperature 7°C B.S., 6°C B.U.; hot
water temperature 45°C; temperature
differential at condenser 5 K; fouling factor
equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to
a 10 m distance from the unit, in free field and
directionality factor equal to Q=2. The noise
data refers to the units without the electric
pump
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
4360
4390
kW
336
357
2,67
2,51
4,59
4,40
kW
335
355,9
2,64
2,49
3,97
3,81
kW
357
385
3,03
2,96
kW
358,1
386,3
3,01
2,94
dB(A)
57
58
dB(A)
89
90
n°
4/4
4/4
n°
2
n° x kW
6x1.2
6x1.2
m³/h
91200
91200
Type
m³/h
57,8
61,4
34
37
kPa
110
102
kPa
149
141
kPa
98
88
kPa
137
127
l
700
700
kW
457
492
78,6/63
84,6/71
m³/h / kPa
kW
87
95
7,5/5
8,2/6
m³/h / kPa
Kg
68
68
Kg
20,8
20,8
4360
4390
kW
126
142
kW
118
130
kW
4,0/5,5
4,0/5,5
V-ph-Hz
V-ph-Hz
A
207
233
A
268
308
A
494
504
A
379
397
A
7,6/10,5 7,6/10,5
4360
4390
mm
2450
2450
mm
2260
2260
mm
3740
3740
Ø
DN80 VIC DN80 VIC DN80 VIC DN100 VIC DN100 VIC DN100 VIC DN100 VIC DN100 VIC
2" VIC
2" VIC
Ø
Kg
2900
2910
(****) Sound power level in dB(A) on the basis
of measurements taken in accordance with UNI
EN- ISO 9614 and Eurovent 8/1 Standards The
noise data refers to the units without the electric
pump
(±) Recovery unit heating capacity Conditions
referring to the unit operating with chilled water
temperature 7°C, differential temperature due to
evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100)
50/60°C (DS). NB. With heat pumps operating
in winter mode with DC active, the heating
capacity available is decreased from the portion
supplied to the desuper- heater.
235
4435
5500
6540
391
446
488
2,44
2,58
2,54
4,34
4,49
4,49
389,9
444,6
486,4
2,42
2,55
2,51
3,74
3,87
3,89
423
472
517
3,04
3,01
2,97
424,3
473,6
518,9
3,02
2,99
2,95
59
59
59
91
91
91
4/4
5/5
6/6
2
2
2
6x1.2
8x1.2
8x1.2
91200
122000
122000
Plates/Shell and tube (STE accessory)
67,2
76,7
83,9
33
38
42
135
123
106
193
182
167
119
117
99
176
177
160
700
700
700
551
614
677
94,8/67 105,6/71 116,4/81 128,3/76 136,7/77 143,9/84
104
118
128
8,9/6
10,1/8
11/8
91
91
91
20,8
33
46
4435
5500
6540
160
173
192
139
157
174
5,5/7,5
5,5/7,5
5,5/7,5
400 – 3 – 50
230 – 1 – 50 / 24 – 1 – 50
263
284
315
326
366
398
549
588
624
430
469
509
10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5
4435
5500
6540
2450
2450
2450
2260
2260
2260
3740
4840
4840
2" VIC
2" VIC
2" VIC 2"1/2 VIC 2"1/2 VIC 2"1/2 VIC
2980
3710
3910
(■) Absorbed current/absorbed power value
without electric pump.
The peak current refers to the unit's most heavy
duty operating conditions.
(°) Data calculated in accordance with EN
14511:2011 under nominal conditions.
The refrigerant charge values are indicative.
Refer to the serial number plate
6590
6635
6670
534
578
606
2,44
2,63
2,61
4,43
4,59
4,58
532,4
576,1
603,9
2,41
2,6
2,58
3,84
3,98
3,97
573
614
646
2,98
3,05
3,02
575
616,1
648,4
2,96
3,03
59
59,5
60
91
92
92,5
6/6
6/6
6/6
2
2
2
8x1.2
10x1.2
10x1.2
122000
152000
152000
91,8
99,4
104,2
38
41
44
106
95
77
134
123
103
98
86
67
125
114
92
700
1000
1000
746
795
837
144
151
159
12,4/9
13/8
13,7/8
94
112
112
46
46
46
6590
6635
6670
219
220
232
192
201
214
5,5/7,5
5,5/7,5
5,5/7,5
360
361
381
458
480
494
684
702
717
549
582
597
6590
6635
6670
2450
2450
2450
2260
2260
2260
4840
5940
5940
3970
4490
4530
3
2