Model EQPH
Nominal cooling capacity (*)
EER
ESEER +
Nominal cooling capacity (*) (°) EN 14511:2013
EER (*) (°) EN 14511:2013
ESEER EN 14511:2013
Nominal heating capacity (**)
COP
Nominal heating capacity (**) (°) EN 14511:2013
COP (*) (°) EN 14511:2013
Sound pressure (***) (*)
Sound power (****) (*)
Sound power with FNR accessory (****)(*)
Scroll/step compressor
Circuits
Fans
Fan nominal air flow
Heat exchanger
Heat exchanger nominal flow water side (*)
Water side heat exchanger nominal pressure drops (*) kPa
Residual head P1 (*)
Residual head P2 (*)
Residual head ASP1 (*)
Residual head ASP2 (*)
Tank water content (ASP1/ASP2)
Nominal heating capacity RC100 (±)
Nominal flow rate/pressure drop RC100 (±)
Nominal heating capacity DS (±)
Nominal flow rate/pressure drop DS (±)
Amount of R410A refrigerant
Polyester oil charge
Electrical data
Absorbed power in summer mode (*) (■)
Absorbed power in winter mode (**) (■)
Pump absorbed power (P1/ASP1) / (P2/ASP2)
Electrical power supply
Auxiliary electrical/control power supply
Summer operation nominal current (*) (■)
Maximum current (■)
Starting current (■)
Starting current with SFS (■)
Pump absorbed current (P1/ASP1) / (P2/ASP2)
Dimensions
Height (a)
Width (b)
Length (c)
Heat exchanger inlet/outlet connections and RC100
DS inlet/outlet connections
Weight
(*) Under the following conditions: condenser
inlet air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5 K; evaporator scaling factor equal
to 0.35x10-4 m2 K/W.
(**) In the following conditions: Evaporator inlet
water temperature 7°C B.S., 6°C B.U.; hot
water temperature 45°C; temperature
differential at condenser 5 K; fouling factor
equal to 0.35x10-4 m2 K/W.
(***) Sound pressure level in dB(A) referring to
a 10 m distance from the unit, in free field and
directionality factor equal to Q=2. The noise
ALLEGATI / ENCLOSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
4385
4415
kW
360
400
3
2,99
4,74
4,73
kW
359,2
399
2,97
2,96
4,1
4,09
kW
386
424
3,22
3,21
kW
386,9
425
3,2
3,2
dB(A)
62,5
63,5
dB(A)
95
dB(A)
86
n°
4/4
4/4
n°
2
n° x kW
8x1.8
8x1.8
m³/h
157500
153000
Type
m³/h
61,9
68,8
24
kPa
121
109
kPa
160
147
kPa
117
104
kPa
156
142
l
700
700
kW
462
516
79,4/40
88,7/45
m³/h / kPa
kW
90
100
7,7/5
8,6/7
m³/h / kPa
Kg
63
Kg
20,8
20,8
4385
4415
kW
120
134
kW
120
132
kW
4,0/5,5
4,0/5,5
V-ph-Hz
V-ph-Hz
A
197
220
A
276
316
A
502
512
A
387
405
A
7,6/10,5 7,6/10,5
4385
4415
mm
2450
2450
mm
2260
2260
mm
4840
4840
Ø
DN80 VIC DN80 VIC DN80 VIC DN100 VIC DN100 VIC DN100 VIC DN100 VIC DN100 VIC
2" VIC
2" VIC
Ø
Kg
3030
3200
data refers to the units without the electric
pump
(****) Sound power level in dB(A) on the basis
of measurements taken in accordance with UNI
EN- ISO 9614 and Eurovent 8/1 Standards The
noise data refers to the units without the electric
pump
(±) Recovery unit heating capacity Conditions
referring to the unit operating with chilled water
temperature 7°C, differential temperature due to
evaporation of 5 K, hot water temperature
produced equivalent to 40/45°C (RC100)
50/60°C (DS). NB. With heat pumps operating
in winter mode with DC active, the heating
236
4460
5525
441
500
2,98
3,05
4,71
4,76
439,9
498,7
538,6
2,95
3,02
4,08
4,1
463
519
3,22
3,22
464,2
520,4
571,5
3,2
3,2
64,5
64,5
96
97
97
86
87
87
4/4
5/5
2
2
2
8x1.8
10x1.8
10x1.8
153000
191000
191000
Plates/Shell and tube (STE accessory)
75,8
86
27
28
32
134
112
194
173
129
104
188
166
700
1000
571
642
98,2/47 110,4/53
120/54
113
126
9,7/8
10,8/9
11,8/10
92
94
112
20,8
33
4460
5525
148
164
144
161
5,5/7,5
5,5/7,5
5,5/7,5
400 – 3 – 50
230 – 1 – 50 / 24 – 1 – 50
243
269
334
374
557
596
438
477
10,5/14,5
10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5 10,5/14,5
4460
5525
2450
2450
2260
2260
4840
5940
2" VIC
2" VIC
2" VIC 2"1/2 VIC 2"1/2 VIC 2"1/2 VIC
3250
3830
capacity available is decreased from the portion
supplied to the desuper- heater.
(■) Absorbed current/absorbed power value
without electric pump.
The peak current refers to the unit's most heavy
duty operating conditions.
(°) Data calculated in accordance with EN
14511:2011 under nominal conditions.
The refrigerant charge values are indicative.
Refer to the serial number plate
6570
6625
6665
540
586
635
2,98
2,93
3,05
4,72
4,74
4,78
584,4
633,5
2,95
2,9
3,02
4,09
4,11
4,15
570
625
661
3,22
3,22
3,22
626,8
662,6
3,2
3,2
3,21
64,5
64,5
65,5
97
97
98
87
87
88
6/6
6/6
6/6
2
2
2
10x1.8
12x1.8
191000
229500
229500
92,8
100,8
109,2
32
35
29
97
100
96
161
128
125
89
90
84
152
118
113
1000
1000
1000
698
763
816
131,2/60 140,3/48
137
151
159
13/10
13,7/9
116
116
146
46
46
46
6570
6625
6665
181
200
208
177
194
205
5,5/7,5
5,5/7,5
297
328
342
406
466
488
632
692
710
517
557
590
6570
6625
6665
2450
2450
2450
2260
2260
2260
5940
5940
6840
4040
4070
4680
6700
662
3
4,77
660,3
2,97
4,14
697
3,24
698,9
3,22
65,5
98
89
6/6
2
12x1.8
113,8
32
84
109
71
96
1000
855
147/54
166
14,3/9
146
46
6700
221
215
5,5/7,5
363
502
725
605
6700
2450
2260
6840
4710