possibility to have an analogue input for the shifting Set-point (CS) via a
4-20mA remote signal;
management of time bands and operation parameters with the possibility
of daily/weekly functioning programs;
check-up and monitoring of scheduled maintenance status;
computer-assisted unit testing;
self-diagnosis with continuous monitoring of the unit functioning status.
Set-point regulation via the AdaptiveFunction Plus with two options:
fixed set-point (Precision option);
set-point sliding (Economy option).
II.2
ACCESSORIES
IMPORTANT!
Only Use original spare parts and accessories.
HITECSA shall not be held liable for damage
caused by tampering with or work carried out by
unauthorised personnel or malfunctions caused by
the use of non-original spare parts or accessories.
II.2.1
Factory Fitted Accessories
P1 – Installation with pump.
PR1 - Installation with a pump on the RC100 recovery circuit
P2 - Installation with increased static pressure pump
PR2 - Installation with an increased head pump on the RC100 recovery
circuit
DP1 – Installation with double pump, including an automatically
activated pump in stand-by.
DPR1 - Installation with a double pump, including one automatically
activated in standby on the RC100 recovery circuit
DP2 – Installation with increased static pressure double pump, including
an automatically activated pump in stand-by.
DPR2 - Installation with increased head double pump, including an
automatically activated pump in standby on the RC100 recovery circuit
ASP1 - Installation with pump and storage tank
ASDP1 - Installation with double pump, including an automatically
activated pump in standby and storage tank
ASP2 - Installation with an increased head pump and storage tank
ASDP2 - Installation with and increased head double pump, including
an automatically activated pump in standby and storage tank
STE – Shell and tube evaporator
CAC - Compressor aphonic ear muffs
BCI – Soundproof compressor box
BCI60 - Compressor technical box soundproofing with high acoustic
impedance (check the table)
BFI - Integral closing soundproofed box of chiller and compressor
compartment. Available in the heat pump units (check table)
BFI60 - Intact soundproofed closing box of the cooling compartment
and compressors with high acoustic impedance material. Available in
the heat pump units (check table)
ADVANCE SE
EQPLB
EQPLBS
EQPHB
EQPHBS
ADVANCE HE-A
EQPL
EQPLBSS
EQPH
BCI-BCI60 otpion / BFI-BFI60 option
EQPHBSS
BCI60 standard / BFI60 option
RS - Compressor intake and supply cocks
DS - Desuperheater. Also active during winter operation (EQPHB)
RC100 - Heat recovery unit with 100% recovery. Refer to the specific
section for more details
FI10 - Modulating condensation control for continuous operation as
chiller up to -10°C of outdoor air temperature (standard versions S)
FI15 - Modulating condensation control with fans with EC motor
(Brushless) for continuous operation as a chiller up to -15°C outdoor air
temperature (standard Q versions)
FIAP - Condensing control with over-pressured fans with EC motor
(Brushless) and available static head according to the following table:
Available static head
Single fan absorption
Average increase in noise of the unit
BCI-BCI60 ACCESSORIES
BCI-option
BCI standard
BCI option / BFI option
BCI standard / BFI option
BCI-BCI60 ACCESSORIES
BCI-BCI60 option
BCI60 standard
Unit with a Ø800mm fan
Up to 150 Pa
Max 2.8 kW
2 dBA
SECTION II :: INSTALLATION AND MAINTENANCE
SFS – Soft Starter compressors.
CR - Power factor correction capacitors
FDL - Forced Download Compressors. Compressor switch-off to limit
the absorbed current and power (digital input)
FNR – Forced Noise Reduction. Forced reduction of noise (digital input
or time band management) - See specific section for more information)
GM - Refrigerant circuit high and low pressure gauges.
RQE - Electrical panel resistance (recommended for low outdoor air
temperatures)
RA - Evaporator antifreeze resistor to prevent the risk of ice formation
inside the exchanger when the machine is switched off (as long as the
unit is not disconnected from the power supply).
RDR - Antifreeze electric heater for desuperheater / heat recovery (DS
or RC100), to prevent the risk of ice formation inside the recovery
exchanger when the machine is switched off (as long is the unit is not
disconnected from the power supply).
RAE1-RAR1 - Antifreeze electric heater for motor-driven pump
(available for P1-DP1-ASP1-ASDP1 installations); to prevent the water
contained in the pump from freezing when the machine is switched off
(as long as the unit is not disconnected from the power supply)
RAE2-RAR2 - Antifreeze electric heater for double motor-driven pumps
(available for DP1-DP2-DPR1-DPR2-ASDP1-ASDP2 installations); to
prevent the water contained in the pump from freezing when the
machine is switched off (as long as the unit is not disconnected from the
power supply)
RAS - 300W antifreeze electric heater for water buffer tank (available
for ASP1-ASDP1- ASP2-ASDP2 installations); to prevent the risk of ice
formation in the water buffer tank when the machine is switched off (as
long as the unit is not disconnected from the power supply).
LDK - Refrigerant leak detector
DSP – Double set-point via digital consensus (incompatible with the CS
accessory).
CS - Scrolling set point via analogue signal 4-20 mA (incompatible with
the DSP accessory).
CMT - Control of minimum and maximum values of power voltage.
BT – Low temperature of water produced.
SS - RS485 interface for serial communication with other devices
(proprietary protocol; Modbus RTU protocol)
EEM – Energy Meter. Measure and display values of the electrical units
EEO – Energy Efficiency Optimizer. Energy efficiency optimisation (only
B-T version)
FTT10 - LON interface for serial communication with other devices
(LON protocol).
RPB - Coil protection networks with accident prevention function (to be
used as an alternative to the FMB accessory).
FMB - Mechanical filters to protect the coils with leaf-protection function
(to use as an alternative to the RPB accessory) (not available for chiller
models).
PTL - Side damping panels within an aesthetic, accident prevention and
anti-intrusion function (to use as an alternative to the RPB accessory
and only for chiller models).
RAP - Unit with pre-painted copper/aluminium condensation coils
(available as an alternative in heat pumps with traditional Cu-AL coils -
refer to the table in "General features")
BRR - Unit with copper/copper condensation coils (available as an
alternative in heat pumps with traditional Cu-AL coils - refer to the table
in "General features")
DVS – High pressure double safety valve with exchanger tap (the valve
is only on the outlet branch. In the case of options, such as DS/RC100
recovery units or tube and shell heat exchangers, please contact the
Pre-Sales department for a quotation and feasibility of the additional
double valves).
IMB - Protective packaging
SAM – Spring anti-vibration mountings (supplied not installed).
MCHXE - AL/AL micro-channel coil with E-coating treatment
58