2.16.7. Frenado con corriente continua (DC braking)

SPEC FUNCTIONS
Parameter
DC Braking mode
(Disabled) 0
(Enabled) 1
Brk time @ stop [ms]
DC braking curr [%]
DC braking delay [ms]
DC Braking
current
Quick stop
QStp opt code
F
Ramp stop
Speed
100 %
Zero
spd
threshold
I DC
DC braking curr
50 %
Figura 2.16.7.1: Función de frenado en corriente continua
—————— Descripción de las funciones ——————
AVy - HE
DC braking
DC braking mode
Brk time @ stop
DC braking curr
DC braking delay
No.
min
904
0
905
0
717
0
716
0
DC Braking mode 1
Brk time @ stop
1000 ms
GA0871g
Value
max
Factory
Configuration
1
0
(OFF)
30000
1000
100
50
65535
500
DC braking mode
T
Speed
100 %
Zero
spd
threshold
I DC
DC braking delay
500 ms
Standard
GA6355g
DC Braking mode
selection
DC Braking mode 0