0210-100-700 Rev-T
Specifikationer
REF 0210-XXX-000-serien
Model:
Håndstykke, batteripakke (Handpiece, battery power pack)
Beskrivelse:
Længde 18,4 cm
Dimensioner
Bredde 3,1 cm
(håndstykke):
Højde 2,7 cm
Masse:
0,78 kg (håndstykke med batteripakke)
2,82 m (skyl)
Slangelængde:
3,05 m (sug)
12 V
Elektrisk strøm:
CE-mærke:
REF 0210-XXX-XXX-serien (inkl. med endelsen E), ekskl.: REF 0210-
100-000S4, REF 0210-114-000S5, REF 0210-165-000, REF 0210-218-
100, REF 0210-900-000 og REF 0210-918-000.
Beskyttelse mod
IPX0
indtrængen (IP):
Udstyrstype:
Driftsform:
Vedvarende
Certificering af produktsikkerhed:
Kun for REF 0211-1XX-
000-serien med eller
uden endelsen E, REF
0211-2XX-XXX-serien med
og uden endelsen E og
REF 0211-022-000:
For REF 0210-0XX-XXX,
REF 0210-1XX-XXX, REF
0210-2XX-XXX, REF
0210-9XX-XXX, alle E- og
S-dele inkluderet, og REF
0207-050-190:
www.stryker.com
Print Date: Nov 02, 2016 02:57:27 PM
0000004059, Rev. T Effective Date: Sep 26, 2016 2:47:57 PM
, otte AA 1,5 V alkaline batterier, internt strømført
Anvendt del Type B
Canadian Standards Association (CSA) International
Canadian Standards Association (CSA)
CAN/CSA-C22.2 No. 601.1-M90, Medical Electrical Equipment — Part 1: General Requirements for Safety (Adopted IEC 60601-1
2d Ed [90])
CAN/CSA C22.2 601.1S1-94, Supplement No 1-94 to CAN/CSA C22.2 601.1-M90
CAN/CSA C22.2 601.1B-98, Amendment 2 to CAN/CSA C22.2 601.1-M90
Underwriters Laboratories (UL)
UL 60601-1 (1st Ed), Medical Electrical Equipment — Part 1: General Requirements for Safety
Canadian Standards Association (CSA) International
International Electrotechnical Commission (IEC)
IEC 60601-1 A1: R:2012 (3.1 Ed), Medical Electrical Equipment — Part 1: General Requirements for Basic Safety and Essential
Performance; Corrigendum 1 (2006); Corrigendum 2 (2007); Amendment 1 (2012)
Canadian Standards Association (CSA)
CAN/CSA-C22.2 No. 60601-1:08, Medical Electrical Equipment — Part 1: General Requirements for Basic Safety and Essential
Performance (Adopted IEC 60601-1:2005 + CORR. 1)
CAN/CSA-C22.2 No. 60601-1:08 TC 2:2011 (Corrigendum 2), Medical Electrical Equipment — Part 1: General Requirements for
Basic Safety and Essential Performance (Adopted IEC 60601-1:2005 + CORR. 1)
CAN/CSA-C22.2 No. 60601-1:14, Medical Electrical Equipment — Part 1: General Requirements for Basic Safety and Essential
Performance (3.1 Ed) (Adopted IEC 60601-1:2005 Edition 3.0 + AMENDMENT 1, 2012-07, MOD)
CAN/CSA-C22.2 No. 60601-1-6:11, Medical Electrical Equipment – Part 1-6: General Requirements for Basic Safety and
Essential Performance – Collateral Standard: Usability
American National Standards Institute (ANSI)/Association for the Advancement of Medical Instrumentation (AAMI)
ANSI/AAMI ES60601-1:2005 (IEC 60601-1:2005, MOD), Medical Electrical Equipment — Part 1: General Requirements for Basic
Safety and Essential Performance
ANSI/AAMI ES60601-1:2005/C1:2009, Medical Electrical Equipment — Part 1: General Requirements for Basic Safety and
Essential Performance – Corrigendum C1
ANSI/AAMI ES60601-1:2005/A2:2010, Medical Electrical Equipment — Part 1: General Requirements for Basic Safety and
Essential Performance – Amendment A2
ANSI/AAMI ES60601-1:2005/(R)2012, AND C1:2009 AND A2:2010(R)2012 (Consolidated text — Edition 3.1), Medical Electrical
Equipment — Part 1: General Requirements for Basic Safety and Essential Performance (IEC 60601-1:2005+A1:2012, MOD)
European Committee for Electrotechnical Standardization (CENELEC)
CENELEC/EN 60601-1:2006/A1:2013 (3.1 ED), Medical Electrical Equipment – Part 1: General Requirements for Basic Safety
and Essential Performance – incorporates Amendment A12
REF 0211-XXX-000-serien
Håndstykke, genopladelig power-pakke
(Handpiece, rechargeable power pack)
0,51 kg (kun håndstykke)
InterPulse genopladelig power-pakke (InterPulse Rechargeable
Power Pack), 7,9 V
Kun REF 0211-100-000, REF 0211-100-000E, REF 0211-110-000,
REF 0211-110-000E, REF 0211-022-000 og REF 0211-024-000.
DA
55