MAINTENANCE

10.3 ClEANING AND DISINFECTING ThE MAChINE

DANGER!
Do not use solvents, thinners or other products classified as toxic, to clean the surfaces.
DANGER!
Ventilate the environment if alcohol-based or flammable disinfectants are used.
ATTENTION!
Do not scrape the surfaces with pointed or abrasive objects.

10.3.1 ClEANING EXTERNAl SURFACES: PlEXIGlASS BODyWORK AND lID

• The stainless steel external surfaces and the Plexiglass lid must be cleaned with a soft cloth or sponge and neutral de-
tergent, following the direction of the satin finish.
• Rinse with a cloth dampened with drinking water.
• It is recommended not to use steel wool, scrapers or abrasive, acidic or aggressive substances, which could irreparably
damage the steel surfaces.
• After cleaning, it is recommended to protect the external surfaces with specific oil-based products for stainless steel.
ATTENTION!
Do not remove the serial number plates during cleaning.
These provide important information regarding the appliance for any technical support.
ATTENTION!
Do not use water jets or vapour to rinse or clean the machine; avoid using water jets and vapour near
the appliance.
Do not spray water on the tank intake slot.

10.3.2 CONTROl PANEl

• It is recommend to use a soft cloth with little detergent and to dry it thoroughly.
• Do not use solvents or alcohol.