MAINTENANCE AND TEChNICAl SUPPORT
8) Check the element is correctly in place along the sealing bar while keeping it taut with the pliers, then tighten the
clamping screw (Fig. 8). Lastly, check the element is taut against the bar (Fig. 9).
9) Use cut-off scissors to remove the excess part of the element (Fig. 10).
10) Put on the new Teflon covering, cutting off any excess at the ends.
11) Put the sealing bar back in the tank, making sure it engages correctly with the electrical contacts (Fig. 11).
Fig. 8
Fig. 9
Fig. 10
Fig. 11
69