11) Use a hexagon wrench to undo the oil filling cap (A) at the top of the pump.
12) Use the same wrench to undo the drain cap (B). Be careful because, as soon as the cap is removed, the oil will flow out
of the pump and directly down the slide into a container. Leave the oil to flow out for about ten minutes (Fig. 8).
13) Refasten the drain cap at the bottom of the pump and refill the pump with oil up to the correct level: in the sight-glass,
the level of oil should be near the top line (Fig. 9).
14) Fasten the filling cap.
15) Put the slide back (C) on the body and tighten the screw fastener.
C
MAX
MIN
72
Rev. 05 - 04/2018 - Cod. 1500458 - Instruction manual for vacuum chamber packaging machines with digital control panel "Serie Bright"
A
B
Fig. 9
Fig. 8