In the scan mode, the backlit LCD displays both the
current temperature (D) and maximum temperature
(C) in Celsius or Fahrenheit (B). The unit will hold
the last reading for 7 seconds after the trigger
is released; the word HOLD appears (E). The
presence of the battery icon (A) indicates a low
battery. The presence of a light bulb (F) will indicate
backlight and LED flashlight are on. When trigger
is pulled triangular icon will be present indicating
laser is on.
Introduction
We are confident you will find many uses for your
handheld non-contact thermometer. Compact,
rugged, and easy to use—just aim, pull the trigger,
and read the temperature in less than a second.
You can safely measure surface temperatures of
hot, hazardous, or hard-to-reach objects without
contact.
How it Works
Infrared thermometers measure the surface
temperature of an object. The unit's optics sense
emitted, reflected, and transmitted energy, which
are collected and focused onto a detector. The
unit's electronics translate the information into a
temperature reading displayed on the unit. The
lasers are used for aiming purposes only.
How to Operate the Unit
Measurement: Quick Start
To measure an object, point the unit at an object,
and pull the trigger. Try to merge the 2 laser
dots on your target into one dot. When using the
lasers, use them only for aiming. When sighting an
object, merge the 2 lasers into one for optimum
temperature reading. For more detailed operating
instructions, see "How to Accurately Measure
Temperature."
Switching °C and °F; Changing
the Battery; Laser/Backlight/
LED On/Off
Before opening the unit's handle to access the
battery and controls, use a Phillips head screw-
driver to remove the base magnet. To open the
unit's handle, push the button near the trigger on
the underside of the unit, and pull the handle down
and forward.
To select °C or °F, slide the top switch (A) up for
Celsius and down for Fahrenheit. To activate the
lasers, backlight and LED flashlight, slide the lower
switch (B) down. Dual lasers and LED flashlight will
turn on when the trigger is pulled. The lasers and
LED flashlight will turn off when the trigger is re-
leased. The backlight will remain on for 7 seconds
after the trigger is released.