Transfer Corona Roller Grounding Block
men
replacing the Re@stration Assembly, be sure to rotate the brass grounding block on the end
of the Transfer Corona Roller to its fill counterclockwise position (the "3:00 O'C1OCK' p osition
as tiewed from the assembly's lefi end) and position it properly on top of the grounding plate as
shown in Figure 6-30.
caution
Failure to position this block properly may result in intermittent hardware failure
indimtions.
Transfer
Registration
Corona Roller
Rollers
I
Grounding
Block
I
(LE~ SIDE VIEW)
Gro~nding
Spring Plate
Figure 6-30. Transfer Corona Roller Grounding Block