Programming digital display

• To enter the parameter programming, press the  button for
a few seconds and the display will show PASS.
• Now press RESET/ ENTER, three zeroes will appear and the
first digit on the right will flash.
• Using the  and  buttons, now enter 273 as the password
and confirm by pressing RESET/ENTER.
Entering the incorrect password will close the menu. Otherwise,
the following menu options can be selected with the  button:
To change the selected parameters:
• Press RESET/ ENTER twice (pressing once shows the value).
• Enter the chosen value with the  and  buttons.
• Press RESET/ ENTER to confirm your setting.
• To quit the programming mode, press the  button.
The following parameters can now be programmed.
en
V alue to be displayed after moving a 10 mm linear
shift.
Factory setting: 10.0 (given in millimetres with one decimal
place)
• First enter the chosen value and close by pressing .
• The decimal place can be moved to the chosen position with
the  button.
• Then confirm by pressing RESET/ ENTER.
Number of decimal places
• Using the  button, select a number between 1 and 5 to
denote the number of places after the decimal point.
• Then confirm by pressing RESET/ ENTER.
 
Defining button assignment
In the form of a 3-digit number, this parameter defines a wide
range of function that can be assigned to the buttons. This
is done by selecting the relevant values at the correct digit
position. (see table)
• Example: in parameter tASt I, enter the value 1 at the 3rd digit
of the code to assign the RESET function to the RESET/ENTER
button.
104
104
104
111 means:
Digit
1.
Button
Value
0
-
1
mm/inch
ABS/REL function
2
-
3
-
4.
-
5
-
6
-
7
-
8
-
* Delayed means that the button must be pressed for 3 seconds
to activate the function.
mm / inch:
Lets you switch between inch mode and mm mode
• The mode is changed by pressing button. The inch modus has
an additional decimal place. Means that parameter nDEC=4 is
not available.
ABS / REL function
L ets you switch between the absolute and relative
position
• Pressing  displays the REL symbol and the current value
is temporarily zeroed.
• It is now possible to measure a relative movement of the
sensors in relation to the current reference point.
• Pressing  again displays the ABS symbol and the absolute
value reappears.
RESET
A fter pressing RESET/ ENTER, the value displayed is
set to zero
• Position the sensor at a known measuring point with measured
value, e.g. at the stop of the measurement path with measured
value = 0.
• In parameter tASt I, enter the value 1 at the 3rd digit of the
code (RESET) and press RESET/ENTER to confirm.
• From now on, the display will be reset to zero after pressing
the RESET/ENTER button once.
2.
3.
RESET/ENTER
-
-
RESET
-
PRESET
-
FAST PRESET
Zero offset
-
0; 1; 2
-
OFFSET
-
FAST OFFSET
-
Delayed RESET*
-
Delayed PRESET*