Area: hold-down clamps
Warning of the risk of hands being crushed
Fig. 8: Labelling – hold-down clamps
Area: protective cover on tools
Warning of the risk of hands being crushed
Fig. 9: Labelling – drilling and insertion unit
Area: motor / drive
Reminder to unplug the mains power plug before changing tools
Fig. 10: Labelling – Motor / drive
Area: entire machine
Reminder to unplug the mains power plug and disconnect
compressed air before changing tools. Main switch does not
disconnect the machine from the compressed air system.
Fig. 11: Labelling – entire machine
Area: protective cover on tools
Labelling on laser beam
Fig. 12: Labelling – laser beam
Area: drill bits
Labelling on turning direction of drill bits
Fig. 13: Labelling – turning direction of drill bits
6. Noise emission
This machine operates at a noise level above 80 dB(a). We
recommend wearing ear protectors at all times to prevent
damage to hearing.
WARNING
Wear ear protection.
7. Aligning / fastening
General information
The machine should be installed on a level, load-bearing
stand with firmly standing feet.
Any machine must be installed in a way that prevents it
from moving about and tipping over.
NOTE
Securely installed machines prevent accidents.

8. Connections required

Main power connection

Connection to the electrical power supply is made by
connecting a 16 A plug
2
appropriate fuse protection.
Care must be taken not to damage electrical supply leads.
These must be changed whenever necessary.
NOTE
Before plugging in, instruct a qualified electrician to
check the socket.
to a prepared socket