To shut down the engine with the standard ignition
switch:
1. Turn the ignition switch counterclockwise to the OFF
position (H, Figure 17). Close and secure the control
panel door. (The control panel door can be padlocked
for added security.)
Note: The electrical system automatically turns off the
tower lights before the engine shuts down to protect
the capacitors.
17
G
F
A
To start the engine with LSC:
WARNING
Automatic Engine Start Hazard
Unexpected start of engine could result in death or
serious injury. Read and follow electronic controller
operator's manual before operating or servicing this
equipment.
1. Open the control panel door (A, Figure 18).
2. Switch the LSC On / Off switch (B, Figure 18) to the
'On' position.
3. To manually start the engine *:
Press the button (C, Figure 19) below the 'Start'
indicator on the high resolution LCD panel. This
indicator will immediately change to 'Stop'.
An alarm will sound for about 5 seconds to warn
that the engine is about to start.
The glow plug indicator will be visible on the LCD
to indicate that the glow plug is on (D, Figure 19).
After the glow plug has warmed the intake, the
engine will begin to crank.
If the engine does not start, the LSC will attempt
the start the engine twice more. If the engine
does not start after three trys, a "failed start" error
code will appear (E, Figure 19).
20
H
C
D
E
B
4. After the engine has started, the lights will turn
on automatically after about 20 seconds. All light
circuit breakers need to be in the 'On' position. With
the LSC switch in the 'On' position, and prior to
starting the engine, the 'Low Oil Pressure" warning
will appear. This is normal. The 'Low Oil Pressure"
warning should go out within 5 seconds of engine
start up. If the Automatic Engine Shutdown System
detects low oil pressure after the engine has
started and stabilized, it will shut down the engine
automatically.
Note: The fuel symbol on the LCD panel will begin
to flash red when low fuel level is detected. The
machine is factory set for a low fuel level of ½ full.
This can be re-set by the user. See separate LSC
Display Module Instruction Manual for re-setting
instructions.
To shut down the engine with LSC:
1. Press the button below 'Stop' on high resolution LCD
panel (A, Figure 19 ('Start' shown)). This indicator will
immediately change to 'Start'. Once the 'Stop' button
has been pressed, the lights will be automatically
sequenced off two at a time. Once all the lights are
off, the engine will shut down.
*Note: For automatic starting and programmed starting
with the LSC, and for complete information on all of the
user programmable items within the LSC, see separate
LSC Display Module Instruction Manual.