HANDLING AND INSTALLATION
WARNING: For Australia only: The water drain connection must be in accordance with AS/
NZS3500 .2 .
To carry out this operation, proceed as follows.
1) Connect the mains water pipe (C) to the appliance's connection pipe (A).
2) Connect the vent pipe (D) to the appliance connection pipe (C) and fix it to the support (E).
The appliance's drain line is fitted with the plug
(B) allowing discharge of the waste deposited .
WARNING: The connection must be made by authorised, skilled personnel, in accordance
with the relevant legal requirements, using appropriate and specified materials . The appliance
is supplied with operating voltage 400V/3N/PE, which can be switched to230V/3/PE (see next
point) (only for model BX61-101-82) . Before doing any work, cut off the mains electricity supply .
Connect the appliance to the mains electricity sup-
ply as follows.
1) If not already present, install an automatic circuit-
breaker (B), protecting only each single appliance
and located close to it, with the following charac-
teristics.
– Thermal breaker device (to adjust see table on
page 3 of the user instructions manual).
– Differential breaker set at 30 mA
– Classe B o C (IEC 898).
2) Undo the screws and remove the side panel (A).
3) Connect the automatic circuit-breaker (B) to the
appliance's terminal board (C) and to the electri-
cal mains supply, in accordance with the electri-
cal system diagram provided at the back of the
manual and using a cable with the following char-
acteristics.
– Weight: ≥ than H05RN-F type (designation 245 IEC 57).
– Temperature of use: ≥70°C.
WARNING: When connecting, take care to connect the phase and neutral lines .
4) Replace the panel and retighten the screws when the operation is complete.
3326461_GB_inst_rev.1
WATER DRAIN CONNECTION
C
A
ELECTRICAL CONNECTION
D
C
B
Ø17
B
A
C
ENGLISH
E
11