CONVERSION OF ELECTRICITY SUPPLY (BX61-101-82)
To carry out this operation, proceed as follows.
1) Disconnect the mains electricity supply.
2) Undo the screws and remove the side panel (A).
3) Fit the jumper (B) to make the electrical connec-
tion of the terminals (C-D) (see attached wiring
diagrams).
4) Use lever (E) to set the overload cutout to 4 A.
5) Change the connections to the motor terminal board (F) as shown in the figure.
6) Remove the carter (G) and change the connections to the heating element terminals (H) as
shown in figure.
400 V
H
7) Replace the carter (G).
8) Replace the panel (A) and screw the screws back
into place.
9) Remove the test voltage indicator sticker from the
dataplate (L) and apply the new one to identify
the voltage being used.
NOTE: On completion of the operation
make sure that there are no malfunctions .
12
400V
-M1
F
-X2=400V
-X3=230V
230V
-M1
F
-X3=230V
-X2=400V
230 V
H
A
B
C D
E
L