Descargar Imprimir esta página

Angelo Po BX61E Manual De Uso página 54

Horno mixto
Ocultar thumbs Ver también para BX61E:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
Alarm
Fault
No water in chamber, or water
H2O
pressure too low.
Oven door opening or closure
OPE
request.
Indicates that cleaning is
CLE
required.
Indicates the need for the
dEC
descaling operation.
The cooking chamber probe
E01
has failed or is not properly
connected.
The product core probe is not
E02
inserted in the food or has
failed.
The steam discharge probe
E03
has failed.
The motor-operated valve is
E04
not positioned correctly.
E05
Safety thermostat failure.
E06
Overload cutouts tripped.
The optional vacuum probe
E08
has failed or is not properly
connected.
Maximum allowed
E09
temperature in chamber
exceeded
Electrical component com-
E10
partment has overheated.
E11
Electronic circuit board dia-
E13
gnostics tripped.
E14
E20
Setup error.
26
Remedy
Check that mains water is
present or adjust the pressure
(see "installation manual"); if
the problem persists inform
the after-sales service.
Inform the after-sales service if
this message continues to be
displayed.
Clean
Perform descaling
Inform the after-sales service.
Check the position of the pro-
duct core probe or inform the
after-sales service if it is faulty.
Inform the after-sales service.
Switch on the oven again and
if the problem persists inform
the after-sales service.
Inform the after-sales service.
Inform the after-sales service.
Press the "Reset" button.
Inform the after-sales service
The oven solves the problem
on its own.
Inform the after-sales service.
Inform the after-sales service.
Notes
Convection cooking cycles
can still be carried out.
The cooking cycle does not
start until the door has been
opened or closed as required.
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
Cooking cycles with product
core probe cannot be carried
out.
Convection and steam coo-
king cycles can still be carried
out.
Convection and steam coo-
king cycles can still be carried
out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
Disconnect and reconnect the
vacuum probe before starting
the cooking cycle.
If the problem persists, call the
after-sales service.
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are ena-
bled so cooking cycles can be
carried out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
The oven's functions are disa-
bled so no cooking cycles can
be carried out.
FAULT
3326461_GB_rev.1

Publicidad

loading

Este manual también es adecuado para:

Bx61erBx101eBx101erBx82eBx122e