SAFETY
► Source of hazard: Electric power
Hazard
Risk of electric
shock caused by
live components
Risk of electric
shock caused by
live parts
When using the appliance, watch out for the following hazards and provide for the countermeasures
indicated below:
► Source of hazard: heat
Hazard
Flammable material
placed on the eva-
cuation area
Contact with hot
working surfaces
Scalding caused by
hot liquids
Flammable material
near or inside the
equipment.
3326461_GB_rev.1
Where or in which situations
does the hazard occur?
• Under protective panels
• Under the control panel
• Under protection covers
• On the appliance and on
the adjacent metal parts
• On the appliance and on
the adjacent metal acces-
sories
HAZARDS AND SAFETY PROVISIONS DURING USE
Where or in which situations
does the hazard occur?
In case of blocked flue
Accidental contact
Tray handling
Presence of flammable ma-
terial near or inside the
equipment.
Countermeasures
• Operations to the electric system
may be carried out by authorised
and qualified staff only, in accor-
dance with the relevant applica-
ble laws.
• Specialist procedure
• Comply with the correct installa-
tion requirements as per section
"Installing the appliance" of the
installation manual.
• Disable the power supply before
removing the protections
• Prevent the appliance from being
powered accidentally.
• Ensure that there is no voltage
• Before commissioning the appli-
ance, check that all electric con-
nections are not damaged
• Use a power supply cable with
the specifications indicated in
section "Electrical connection" of
the installation manual.
• Before appliance commissioning,
check that electrical connections
are securely fixed
• Before commissioning, make sure
that the appliance and its metal
accessories are connected to a
system for equipotential bonding
Countermeasures
• Training of personnel
• Training of personnel and
warning plate in place on
the appliance and in the
user manual
• Training of personnel
• Formazione del personale
ENGLISH
Safety device
• Protection
panels
• System switch-
disconnector
Equipotential
bonding system
Safety device
None
None
PPE as required
by the applica-
ble laws in the
country of use.
Nessuno
5