Omni On (Controller number 125)
status
2nd byte
3rd byte
BnH
7DH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
* The same processing as when All Note Off is received will be done. The
instrument will not be set to OMNI ON.
* Not received in Performance mode if Rx Switch parameter (PERFORM/
MIDI/Part MIDI) is OFF.
Mono (Controller number 126)
status
2nd byte
3rd byte
BnH
7EH
mmH
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
mm=Mono number
: 00H - 10H (0 - 16)
* The same processing as when All Note Off is received will be done, and the
Key Assign parameter (PATCH/Common/Common Control) will be set to
SOLO.
* Not received in Performance mode if Rx Switch parameter (PERFORM/
MIDI/Part MIDI) is OFF.
Poly (Controller number 127)
status
2nd byte
3rd byte
BnH
7FH
00H
n=MIDI channel number
: 0H - FH (ch.1 - ch.16)
* The same processing as when All Note Off is received will be done, and the
Key Assign parameter (PATCH/Common/Common Control) will be set to
POLY.
* Not received in Performance mode if Rx Switch parameter (PERFORM/
MIDI/Part MIDI) is OFF.
System Realtime messages
Active Sensing
status
FEH
* When an Active Sensing message is received, the unit will begin monitoring
the interval at which MIDI messages are received. During monitoring, if
more than 420 ms passes without a message being received, the same
processing will be done as when All Sound Off, All Note Off, and Reset All
Controllers messages are received. Then monitoring will be halted.
System Exclusive messages
status
data byte
status
F0H
iiH, ddH, ......, eeH
F0H
: System Exclusive message status
ii = ID number
: This is the ID number (manufacturer ID) that spe-
cifies the manufacturer whose exclusive message
this is. Roland's manufacturer ID is 41H.ID num-
bers 7EH and 7FH are defined in an expansion
of the MIDI standard as Universal Non-realtime
messages (7EH) and Universal Realtime
Messages (7FH).
dd,..., ee = data
: 00H - 7FH (0 - 127)
F7H
: EOX (End Of Exclusive)
Of the System Exclusive messages received by this device, the data of messa-
ges related to Mode settings and the Data Request (RQ1) messages will be set
automatically.
System Exclusive messages related to Mode settings
These messages are used to initialize the instrument to GM mode, or to switch
from one mode to another mode.
"GM System On" and "GM System Off" use Universal Non-realtime message
format.
GM System On
"GM System On" is a command message that resets the internal settings of
the instrument to the GM initial state (General MIDI System - Level 1). A GM
instrument that receives this message will automatically enter a state in which
it can correctly perform a GM score.
status
data byte
status
F0H
7EH, 7FH, 09H, 01H F7H
Byte
Remarks
F0H
Exclusive status
7EH
ID number
(Universal Non-realtime message)
7FH
device ID
(Broadcast)
09H
sub ID#1
(General MIDI Message)
01H
sub ID#2
(General MIDI On)
F7H
EOX
(End Of Exclusive)
F7H
Capítulo 12. Material suplementario
* Not received when the Rx.GM-ON Message parameter (SYSTEM/MIDI/
MIDI Param 1) is OFF.
GM System Off
When this messages is received, this instrument will return to the performan-
ce mode.
status
data byte
F0H
7EH, 7FH, 09H, 02H
Byte
Remarks
F0H
Exclusive status
7EH
ID number
(Universal Non-realtime message)
7FH
device ID
(Broadcast)
09H
sub ID#1
(General MIDI Message)
02H
sub ID#2
(General MIDI Off)
F7H
EOX
(End Of Exclusive)
* Not received when the Rx.GM-ON Message parameter (SYSTEM/MIDI/
MIDI Param 1) is OFF.
Data transmission
This instrument can use exclusive messages to exchange many varieties of
internal settings with other devices.
The model ID of the exclusive messages used by this instrument is 6AH.
Data Request 1 RQ1
This message requests the other device to transmit data. The address and size
indicate the type and amount of data that is requested.
When a Data Request message is received, if the device is in a state in which it
is able to transmit data, and if the address and size are appropriate, the
requested data is transmitted as a Data Set 1 (DT1) message. If the conditions
are not met, nothing is transmitted.
status
data byte
F0H
41H, dev, 6AH, 11H, aaH, bbH, ccH, ddH, ssH, ttH, uuH, vvH, sum
Byte
Remarks
F0H
Exclusive status
41H
ID number
(Roland)
dev
device ID
(dev : 10H - 1FH)
6AH
model ID
(XP-60/XP-80)
11H
command ID (RQ1)
aaH
address MSB
bbH
address
ccH
address
ddH
address LSB
ssH
size MSB
ttH
size
uuH
size
vvH
size LSB
sum
checksum
F7H
EOX
(End Of Exclusive)
* The size of data that can be transmitted at one time is fixed for each type of
data. and data requests must be made with a fixed starting address and
size. Refer to the address and size given in "5. Parameter address map."
(p.221)
* For the checksum, refer to page 227.
* This message is not received if the Rx.Sys.Excl parameter
(SYSTEM/MIDI/MIDI Param 1) is OFF.
* This message is not received in GM mode.
Data Set 1
DT1
This message transmits the actual data, and is used when you wish to set the
data of the receiving device.
status
data byte
F0H
41H, dev, 6AH, 12H, aaH, bbH, ccH, ddH, eeH, ... ffH, sum
status
F7H
status
F7H
status
F7H
217