3
Technical data
Electrical data
•
Supply voltage
•
Power consumption
•
Model
•
Overvoltage cat.
Dimensions
•
Weight
•
Dimensions
•
Cable length
Typical application parameters (example of Standard exchange module)*
Range of applications
•
Plasma temperature*
•
Distance for treatment*
•
Width for treatment*
•
Speed*
Operating conditions
•
Air humidity
•
Temperature
•
Degree of contamination 2
Storage conditions
•
Air humidity
•
Temperature
Gas connection
•
Gas types
•
Gas flow rate / gas inlet
pressure
•
Quality
•
Connection
*
These values are rough guidelines. Depending on the treated material, process parameters, following processes and
process requirements, the actual parameters may deviate significantly in both directions from the typical treatment
speeds (also see chapter 6). Due to the low plasma temperature of below 50 °C, a slower treatment speed is not
considered critical.
4
Transport/Storage
•
Store the device in a dry place. This will prevent the electrical contacts from corroding.
•
Protect the device from dirt and foreign objects.
•
Protect the device from falls or other hard impacts.
14
24 V DC
max. 18 W
Integration unit with gas connection
Category I (DIN EN 60664-1 VDE 0110-1
386 g total device with module, without connecting lines
(175 g module carrier / 211 g driver unit)
40 x 150 x 72 mm (WxHxD); without connecting lines / module
0.3 m
Precision cleaning
Adhesive bonding
< 50 °C (at 5 mm distance)
Compressed air 5 to 29 mm; nitrogen 5 to 50 mm
1-15 mm/s
10-150 mm/s
< 80% rel. (non-condensing)
10 – 40 °C; 50 – 104 °F
< 80% rel. (non-condensing)
0 – 60 °C; 32 – 140 °F
- Compressed air (purified, free of oil and lubricants)
- Nitrogen (industrial gases free of particles and oil)
- Additional gas types only after approval from relyon plasma.
8 to 20 l/min; max. 2 bar
Compressed air 1.4.1 acc. to ISO 8573.1
Nitrogen 2.8 (N2) acc. to DIN EN ISO 14175:N1
Hose outer diameter Ø 4 mm (quick coupling)
)
Printing
2 – 10 mm
100-1500 mm/s