5.9
Installation of several devices
When installing multiple devices, be sure to observe minimum distances beside the
exchange modules. If these distances are not observed, discharges from the individual
exchangeable modules may interfere with each other, adversely affecting the treatment
result or even cause damage to the unit. If several devices are attached in parallel, the
minimum distance is already determined by the width of the device.
Below is an example of a side-by-side line-up solution and a line-up solution with modules
offset by half at the back.
24
BA-PZ3_i_ML / F0354902