7.7
Commissioning a device with CAN bus communication
Ensure that an exchange module is installed in the device.
Please note the instructions relating to electrically conductive objects (Figs. 5 to 8).
Ensure that sufficient suction extraction is assured in the work area.
Ensure that the module carrier has a functioning gas supply.
Ensure that a unique CANopen address is set on each device. The address is set at the
DIP switches in the binary system. A list of possible addresses can be found in the
documentation for the EDS file (see chapter 7.8).
Ensure that there is a bus termination on the last device connected to the bus (see
chapter 5.7).
Ensure that all the devices are connected to the CAN bus (see chapter 5.7).
Ensure that each device has a supply voltage of 24 V.
Set up the PZ3-i devices in your PLC with the help of the EDS file (see chapter 7.8).
Send the 'Plasma On' signal to the connected devices.
7.8
CANopen object directory
The CANopen object directory is available online through our website.
You can also find the address settings and the EDS file there.
You can access the data in the Downloads section on our website:
https://www.relyon-plasma.com/piezobrush-pz3-i/?lang=en
32
BA-PZ3_i_ML / F0354902