6.4.2.3
Check oil in the sealing chamber
+
-
Fig. 5: Sealing chamber: Check oil
6.4.3
Stationary wet well installation
Installation and operating instructions Wilo Motor HC 20.1 + EMU FA, Rexa SUPRA, Rexa SOLID
Installation and electrical connection
+
Add the oil to the sealing chamber
-
Drain the oil in the sealing chamber
‡
Pump is not installed.
‡
Pump is not connected to the mains.
‡
Protective equipment has been put on!
1. Place the pump upright on a firm surface.WARNING! Risk of hands being crushed.
Ensure that the pump cannot fall over or slip away!
2. Place a suitable tank to collect the operating fluid.
3. Unscrew the screw plug (+).
4. Unscrew screw plug (-) and drain the operating fluid. If a shut-off ball cock is in-
stalled on the outlet opening, open the shut-off ball cock.
5. Check the operating fluid:
⇒ If the operating fluid is clear, reuse operating fluid.
⇒ If the operating fluid is contaminated (black), fill with new operating fluid. Dis-
pose of operating fluid in accordance with the local regulations!
⇒ Notify customer service if the operating fluid contains swarf!
6. If a shut-off ball cock is installed on the outlet opening, close the shut-off ball
cock.
7. Clean the screw plug (-), replace the seal ring and screw it back in. Max. tightening
torque: 8 Nm (5.9 ft·lb)!
8. Pour the new operating fluid in through the hole for the screw plug (+).
⇒ Comply with the specifications for operating fluid type and quantity! When re-
cycling the operating fluid, check the quantity and if required adjust it!
9. Clean the screw plug (+), replace the seal ring and screw it back in. Max. tightening
torque: 8 Nm (5.9 ft·lb)!
NOTICE
Pumping problems due to water level being too low
If the fluid is lowered too much, separation of the volume flow may occur. Further-
more, air cushions may form in the hydraulic system, resulting in undesirable beha-
viour during operation. The minimum permissible water level must reach the upper
edge of the hydraulics housing!
The pump is installed in the fluid for the wet well installation. For this, a suspension unit
must be installed in the chamber. On the pressure side, the on-site pipe system is con-
nected to the suspension unit and on the suction side to the pump. The connected pipe
system must be self-supporting. The suspension unit must not support the pipe sys-
tem!
en
167