All manuals and user guides at all-guides.com
B
SPIDER MAX 500
10. INJECTION LED CIRCUIT
10.1 Circuit diagram
Central unit
ground
CENTRAL UNIT
Dashboard
connector
Injection
Key switch
+ Battery
Sch. 3
Every time the key switched is moved to the "ON" position, the injection led receives the command and blinks for 5
seconds.
The diagnostic multimeter is not programmed to perform a check of the circuit.
Proceed as follows:
- Key switch on the "ON" position;
- Lift the side stand;
- Emergency switch on "RUN"
- The injection led goes on for 5 seconds.
The system is working.
Connect the testing wiring across the system and the central unit.
54
12/04