Select the diagnostic multimeter menu from the "PARAMETERS" function.
Make sure that the central unit can recognise the following limit positions:
gas valve min. opening
gas valve max. opening
Check the adjustment of the flexible control transmissions of
the gas valve.
Open the throttle valve gradually, make sure that the value expressed in
mV increases gradually and according to the opening change.
The gas valve position signal is normal.
Connect the testing wiring to the system connector.
Do not connect the connection to the central unit.
All manuals and user guides at all-guides.com
Parameters
Immobilizer
Errors
Delete errors
Active diagnostics
CO calibration
Main
Restore or replace.
F. 88
104 12/04
Throttle value mV.
Battery voltageV
11.7
Stepper motor steps
Engine running
Syncr. panel
Min. or max. throttle YES
1/8
Parameters
B
817
96
NO
NO
2/3