SPIDER MAX 500
Check the resistance of the coil main circuit
H.T.(see picture).
Main circuit resistance = 0,5 Ω Ω Ω Ω Ω ± 8%
Check for the main circuit insulation from the
ground. Carry out the measurement across the
main circuit two terminals and the ground.
Main circuit-ground= infinitive (>1MΩ Ω Ω Ω Ω ).
F. 70
All manuals and user guides at all-guides.com
Disconnect the connector across the motorcycle and injection system.
Repeat the check of the two section insulation from the ground.
Repair or replace the concerned connections.
Repeat the check from the "ACTIVE DIAGNOSTICS" menu, H.T. coil
simulation.
Delete the errors stored in the memory.
91
F. 69
12/04