SPIDER MAX 500
Start the engine and let it warm up until the following conditions are reached:
- coolant temperature = above 70°C
- intake air temperature = 25 ÷ 30°C
Start the exhaust gas analyser and verify the following conditions:
- CO = 1,25±0,25%
- CO2 = 14,50±1%
The adjustment is correct.
In case of different CO values, adjust the idling injection time.
Select the diagnostic multimeter menu from the "CO CALIBRATION" function.
Enable the adjustment function.
"TRIMMER VALUE" is displayed.
The indicated number can be either positive or negative.
TRIMMER VALUE
- 25
OK TO SAVE
ESC TO EXIT
CO CALIBRATION
115 12/04