Installation
Gas Connection
Connect the oven to the gas line with the proper
type of gas according to Local and National In-
stallation Standards.
SG3240G ovens are rated at 32,2 kW/Hr. (110,000
BTU/Hr.) Each oven has been adjusted at the fac-
tory to operate with the type of gas specified on the
rating plate attached to the left side of the operator
control.
Each oven is supplied with a regulating gas valve
to maintain the proper gas pressure. This valve
assembly is essential to the proper operation
of the oven and should not be removed or re-
placed with another model unless approved by
Blodgett.
DO NOT INSTALL AN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS
Type of
Inlet
Gas
Pressure
mbars
G25
25
G20
20
G20/G25
G20/G25
20/25
20/25
G30
30/50
G31
30/37/50
NOTE: * Use with pre-injector of 4.6 mm.
Burner
Pressure
mbars
13,5
8,7
Totally Inscrewed
Totally Inscrewed
Pressure Regulator
20
25
22
SUPPLY UNLESS THE SUPPLY EXCEEDS THE
MAXIMUM.
The oven and its individual shutoff valve must be
disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of 1/2 psig (3.45kPa).
The oven must be isolated from the gas supply
piping system by closing its individual manual
shutoff valve during any pressure testing of the
gas piping system at test pressures equal or less
than 1/2 psig (3.45kPa).
Setting Equipment for Other Types of Gas
Contact a qualified service agency to convert to
another type of gas.
Injector
Air
Diameter
Opening
mm
mm
4,8
10
4,8
10
4,8*
4,8
10
10
2,8
10
2,8
10
Pilot
Standard
Injector
Delivery
mm
Value kW (H
2 x 0,63
32,2 Nat. Gas
2 x 0,63
32,2 Nat. Gas
2 x 0,63
2 x 0,63
32,2 Nat. Gas
32,2 Nat. Gas
2 x 0,30
32,2 Butane
2 x 0,30
32,2 Propane
)