Technical information
13. Measures for temporary storage
The machine is designed for immediate installation and
start-up. The following measures must be taken if this does
not take place within a reasonable period of about 3 months
after receiving the machine:
• Coat bare metal parts with corrosion-inhibiting oil.
• Cover the control system, electrical devices/operating
equipment, drive motors to protect them from moisture
and dust.
• Taking particular care, cover / use adhesive tape to seal off
cable inlets into terminal boxes and plugs.
• Protect wiring harnesses from vermin. Mice and rats are
particularly partial to highly flexible cables.
• Store the machine in a dry, frost-free room.
• Also observe the storage instructions.
Apply appropriate measures to protect the stored machine
from tipping over, falling objects, impact from external
force (e.g. industrial vehicles bumping into it), knocks and
vibrations.
en
14. Protection measures at the site of installation
For all installation measures and connecting work, observe
the regulations, warnings and information on "health, safety
and environmental protection" in this operating manual.
For the machine to operate safely, it must be properly
installed / assembled by qualified personnel in observance
of the warnings and regulations provided in this operating
manual.
In particular, observe the installation and safety regulations
regarding work on high voltage systems and the regulations
of the electric power provider. Also make sure staff are
appropriately qualified.
Danger!
Failure to observe these requirements may result in
serious damage to health and property.
• Before attempting any measure, familiarise yourself with
the hazards prevailing at the site of installation and/
or presented by the materials being machined or by the
auxiliary materials (solvents / cleaning agents etc.) you
will be handling.
• Close off the work area to prevent access by unauthorised
persons.
• Observe the applicable national and international
provisions on safety.
Warning!
Welding work must never be performed on the
machine.
118
15. Safety guards to be provided by the owner
Safety guards provided by the owner must be easily
accessible and in full working order after installing the
machine. They must not interfere with the machine's own
safety guards in operation on site.
The site of installation must be selected in such a way
that will also allow repairs to be performed at a later date
without physical obstruction.
16. Permissible ambient conditions
• The machine must only be installed and operated in dry
rooms.
• The machine is not explosion-protected. The machine must
not be installed near painting facilities.
• Provide a supply of fresh air to the fan cowls on electric
motors.
• Avoid any external mechanical strain on the machine.
17. Removing preservatives
The machine is only coated with preservatives for
transportation.
• Clean dust and shipping dirt from the machine with a dry
cloth.
• Never use cold-cleaning products, nitrocellulose thinner or
other aggressive chemicals!
• Remove all transport braces. These should be kept for later
re-use.