The distance can be checked best by inserting two 5 mm pins
into the drillings. For this, you must use a calliper and measure
from the outer edge of the pins
. This must produce a
8
dimension of 37 mm (32 mm distance between the drillings
+ 2 times 2.5 mm = 37 mm)
8
7
en
If the dimension differs, the continuation stop must
be readjusted.
For this, undo the screw at the pendulum and tighten
or slacken the grub screw using a hexagon socket spanner
(1 turn = 0.8mm)
.