Setting Drilling Depth; Drilling Penetration Rate (End-Position Damping) - Hettich BlueMax Mini Modular Instrucciones De Servicio

Ocultar thumbs Ver también para BlueMax Mini Modular:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 278
Setting up

Setting drilling depth

The stop limits downward drilling-stroke movement.
The drilling stroke can be selected to suit any panel thickness.
To do this, undo locknut
required direction.
Always re-tighten the locknut to avoid differences in drilling
depth.
Afterwards, carry out a trial drilling and check drilling depth
using a calliper gauge.
en

Drilling penetration rate (end-position damping)

The drill lowering rate can be limited so as to obtain good
drilling results. The rate is reduced just before the drill bits reach
the panel.
Lower end-position damping is adjusting using setscrew
the stroke cylinder
at the rear of the machine.
4
Drilling penetration rate can be reduced or increased by turning
the adjustment screw.
Setscrew
in the valve is used for setting the length of time the
3
hold-down clamps remain in position for after drilling (drilling
hole lines only).
Setscrew
adjusts drilling penetration rate. This setting needs
7
to be made when changing over from pushbutton to foot valve.
When operating the machine with the foot valve, drilling
penetration rate is adjusted at setscrew
Check the setting by making a test drilling.
Drill overrun
The drill overrun can be adjusted. This is factory-set. To change
the drill overrun, turn the screw on the throttle non-return
valves
. Check the setting by making a test drilling.
9
140
in stop
and turn this in the
2
1
.
8
1
2
8
7
in
5
3
4
5