GENERAL INFORMATION
HOW TO GET STARTED SUMMARY
Calibrate Pump Flow Rate Output (mandatory)
From the Configuration menu, select GPD/LPD Calibration, and enter your pump's ACTUAL maximum flow rate
output. Refer to illustration below.
Configuration
- Units
- Clock
- Calibration
IMPORTANT!
The pump's ACTUAL maximum flow rate entry:
・ Affects flow rate output displayed on the screen during operation in all modes.
・ Contributes to overall calculation of flow rate output in the PPM modes.
2
Program Applicable Pump Parameters
In Configuration menu, program applicable pump parameters, refer to chart below.
Pump Parameters
Display Brightness
Units
Clock
Leak Detect
Tube Timer
Password
Output Relays
Signal Calibration
Reset Totalizer
Modbus Setup
3
Select Mode of Operation
In Control Modes menu, select your mode of operation.
4
Program the Options
In your selected control mode, program the options relevant to your application.
5
Run the Pump
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
Calibration
- GPD/LPD Calibration
- Signal Calibration
- GO TO CONFIG MENU
Description
Optimal setting is < 50% for extended periods.
Default is Gallons; enter Liters, if preferred.
24-hr format. Enter current time of day and day of the week.
Calibrate sensitivity to distinguish between water & your chemical.
Enter number of hours you want pump to run before display
shows TUBE CHANGE.
Program a password to prevent unauthorized changes to pump settings.
Three individual relays available; rated for 24VDC @ 50mA max.
Program communication for:
• S Series to back-up S Series
• S Series to another device
If factory settings are not sufficient, calibrate the pump using a
process meter or powered transmitter.
Option to reset the total tallied amount of water treated.
Modbus RTU over RS-485 capability; pump firmware 3.02.02 or higher
Enter max pump flow
_ _ 0.0 GPD
adjust
12
set
Control Mode
All
All
All
All
All
All
All
4-20mA, 0-10VDC
Pulse, Hall Effect, PPM
Manual, 4-20mA, 0-10VDC, Pulse