Descargar Imprimir esta página

Stenner Pumps S Serie Manual De Instalación Y Mantenimiento página 33

Dosificador peristáltico
Ocultar thumbs Ver también para S Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

CONTROL MODES MENU
4-20mA
page 2 of 3
To program the pump for 4-20mA control mode, set the response curve in Program Settings, return to
the 4-20mA Control menu and program the desired options under Alarm Settings, then exit to the
Main Menu via the Go To Main Menu option.
NAVIGATION
Moves up in a menu, toggles
between options, or increase a value
Holding the
or
button causes the numbers to change rapidly.
Control Mode
- Manual
- 4-20mA
- 0-10VDC
Continued on next page
S Series FW 4.01.02 US and Canada 800.683.2378, International 904.641.1666 www.stenner.com
continued
Moves down in a menu, toggles
between options, or decreases a value
4-20mA
- Program Settings
- Alarm Settings
- Go to Main Menu
4-20mA
- Program Settings
- Alarm Settings
- Go to Main Menu
4-20mA
- Program Settings
- Alarm Settings
- Go to Main Menu
To Main Menu
Moves one step back in
a menu, when permitted
Minimum Signal
_4.0 mA
adjust
set
Speed at Min mA
_ _ 0%
adjust
set
Maximum Signal
20.0 mA
adjust
set
Speed at Max mA
100 %
adjust
set
To 4-20mA menu
33
Sets a value in a menu
Set the response curve by entering the
Minimum Signal, the % pump speed at
Minimum Signal, and the % pump
speed at Maximum Signal.
When ENTER is pressed for the
final digit, the display will return
to the 4-20mA menu.

Publicidad

loading

Este manual también es adecuado para:

S30S40S50